Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
33
matching recommendationsNAICS | 3363 | Motor Vehicle Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0475 # 02 Y:2012 | 02 | 2012 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,377 | $235 | Implemented |
IA0475 # 06 Y:2012 | 06 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,229 | $16,000 | Not Implemented |
IA0475 # 03 Y:2012 | 03 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,726 | $240 | Not Implemented |
IA0475 # 04 Y:2012 | 04 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,097 | $1,375 | Not Implemented |
IA0475 # 08 Y:2012 | 08 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,902 | $4,500 | Not Implemented |
IA0475 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $960 | $433 | Implemented |
IA0475 # 01 Y:2012 | 01 | 2012 | INSTALL OCCUPANCY SENSORS | $1,055 | $1,160 | Implemented |
IA0475 # 07 Y:2012 | 07 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,517 | $550 | Not Implemented |
IA0475 # 09 Y:2012 | 09 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,468 | $160 | Not Implemented |
IA0447 # 07 Y:2010 | 07 | 2010 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $525 | $5,000 | Implemented |
IA0447 # 06 Y:2010 | 06 | 2010 | REPLACE BOILER | $29,283 | $53,900 | Implemented |
IA0447 # 05 Y:2010 | 05 | 2010 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $6,801 | $42,100 | Not Implemented |
IA0447 # 04 Y:2010 | 04 | 2010 | REDUCE VENTILATION AIR | $3,072 | $2,000 | Implemented |
IA0447 # 03 Y:2010 | 03 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,599 | $1,140 | Implemented |
IA0447 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,514 | $13,439 | Implemented |
IA0447 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $745 | $487 | Not Implemented |
IA0356 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,734 | $6,677 | Implemented |
IA0356 # 07 Y:2004 | 07 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $254 | $120 | Implemented |
IA0356 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $2,860 | $4,628 | Not Implemented |
IA0356 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $536 | $752 | Implemented |
IA0356 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,645 | $2,290 | Implemented |
IA0356 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,880 | $200 | Implemented |
IA0356 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,212 | $349 | Implemented |
IA0310 # 06 Y:2003 | 06 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $204 | $0 | Implemented |
IA0310 # 05 Y:2003 | 05 | 2003 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $12,468 | $7,349 | Implemented |