Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
204
matching recommendationsNAICS | 336340 | Motor Vehicle Brake System Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0049 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,012 | $0 | Implemented |
MZ0049 # 04 Y:2010 | 04 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $180 | $170 | Implemented |
MZ0049 # 05 Y:2010 | 05 | 2010 | INSTALL OCCUPANCY SENSORS | $5,075 | $6,650 | Implemented |
MZ0049 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,075 | $3,960 | Not Implemented |
MZ0049 # 07 Y:2010 | 07 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $217 | $150 | Implemented |
MZ0049 # 08 Y:2010 | 08 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,410 | $2,800 | Implemented |
MZ0049 # 09 Y:2010 | 09 | 2010 | COMBINE UTILITY METERS | $288 | $0 | Not Implemented |
MZ0049 # 10 Y:2010 | 10 | 2010 | REDUCE SCRAP PRODUCTION | $3,156 | $0 | Implemented |
MZ0049 # 11 Y:2010 | 11 | 2010 | USE OPTIMUM TEMPERATURE | $1,228 | $0 | Not Implemented |
MZ0049 # 12 Y:2010 | 12 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,900 | $37,600 | Implemented |
GT0868 # 01 Y:2009 | 01 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $27,075 | $19,000 | Not Implemented |
GT0868 # 02 Y:2009 | 02 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,414 | $3,000 | Not Implemented |
GT0868 # 03 Y:2009 | 03 | 2009 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $10,079 | $12,000 | Not Implemented |
GT0868 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,232 | $60,000 | Implemented |
GT0868 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,204 | $4,676 | Implemented |
GT0868 # 06 Y:2009 | 06 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,368 | $4,750 | Implemented |
UM0348 # 01 Y:2009 | 01 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $56,000 | $6,000 | Implemented |
UM0348 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $51,000 | $3,000 | Implemented |
UM0348 # 03 Y:2009 | 03 | 2009 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $30,000 | $62,000 | Not Implemented |
UM0348 # 04 Y:2009 | 04 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $22,700 | $12,400 | Not Implemented |
UM0348 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,200 | $35,689 | Implemented |
UM0348 # 06 Y:2009 | 06 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,900 | $200 | Implemented |
UM0348 # 07 Y:2009 | 07 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $6,200 | $15,000 | Implemented |
UM0348 # 08 Y:2009 | 08 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,300 | $3,900 | Not Implemented |
UM0348 # 09 Y:2009 | 09 | 2009 | INSTALL OCCUPANCY SENSORS | $3,400 | $7,400 | Not Implemented |