Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,719
matching recommendationsNAICS | 33641 | Aerospace Product and Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0086 # 04 Y:2004 | 04 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $90,000 | $50,000 | Implemented |
MI0086 # 05 Y:2004 | 05 | 2004 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $120 | $15 | Not Implemented |
MI0086 # 06 Y:2004 | 06 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,490 | $610 | Implemented |
MI0086 # 07 Y:2004 | 07 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $340 | $386 | Implemented |
MI0086 # 08 Y:2004 | 08 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,615 | $490 | Implemented |
MI0080 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,571 | $10,600 | Not Implemented |
MI0080 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,438 | $2,300 | Implemented |
MI0080 # 03 Y:2004 | 03 | 2004 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $93,161 | $57,760 | Not Implemented |
MI0080 # 04 Y:2004 | 04 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,222 | $160 | Implemented |
MI0080 # 05 Y:2004 | 05 | 2004 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $822 | $60 | Implemented |
TA0073 # 01 Y:2004 | 01 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $22,670 | $760 | Implemented |
TA0073 # 02 Y:2004 | 02 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $18,180 | $16 | Implemented |
TA0073 # 03 Y:2004 | 03 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,225 | $60 | Implemented |
TA0073 # 04 Y:2004 | 04 | 2004 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $8,315 | $1,360 | Implemented |
TA0073 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,700 | $16 | Implemented |
TA0073 # 06 Y:2004 | 06 | 2004 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $4,180 | $630 | Implemented |
TA0073 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,450 | $120 | Implemented |
TA0073 # 08 Y:2004 | 08 | 2004 | INSULATE BARE EQUIPMENT | $2,400 | $640 | Implemented |
TA0073 # 09 Y:2004 | 09 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $60,865 | $0 | Implemented |
TA0073 # 10 Y:2004 | 10 | 2004 | SHUT OFF AIR CONDITIONING IN WINTER HEATING SEASON | $56,500 | $0 | Implemented |
TA0073 # 11 Y:2004 | 11 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,200 | $0 | Implemented |
TA0073 # 12 Y:2004 | 12 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,400 | $0 | Not Implemented |
UU0060 # 01 Y:2004 | 01 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,202 | $13,200 | Implemented |
UU0060 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,695 | $4,800 | Not Implemented |
UU0060 # 03 Y:2004 | 03 | 2004 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $5,059 | $4,000 | Implemented |