Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
379
matching recommendationsNAICS | 336412 | Aircraft Engine and Engine Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0268 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $310 | $385 | Implemented |
SU0268 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $39,769 | $83,044 | Implemented |
SU0268 # 07 Y:2008 | 07 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $781 | $1,451 | Not Implemented |
SU0268 # 08 Y:2008 | 08 | 2008 | INSTALL OCCUPANCY SENSORS | $318 | $674 | Implemented |
SU0268 # 09 Y:2008 | 09 | 2008 | OPTIMIZE PLANT POWER FACTOR | $11,006 | $39,533 | Not Implemented |
WV0372 # 10 Y:2008 | 10 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,153 | $460 | Not Implemented |
WV0372 # 09 Y:2008 | 09 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,523 | $0 | Implemented |
WV0372 # 08 Y:2008 | 08 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,560 | $2,750 | Not Implemented |
WV0372 # 07 Y:2008 | 07 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $3,550 | $890 | Implemented |
WV0372 # 06 Y:2008 | 06 | 2008 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $5,074 | $4,500 | Implemented |
WV0372 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,593 | $8,011 | Implemented |
WV0372 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,107 | $540 | Not Implemented |
WV0372 # 03 Y:2008 | 03 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $10,188 | $511 | Implemented |
WV0372 # 02 Y:2008 | 02 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,813 | $2,000 | Implemented |
WV0372 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28,998 | $34,945 | Not Implemented |
DL0004 # 01 Y:2007 | 01 | 2007 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $39,666 | $0 | Implemented |
DL0004 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,000 | $97,570 | Not Implemented |
DL0004 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,160 | $800 | Not Implemented |
DL0004 # 04 Y:2007 | 04 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,933 | $500 | Not Implemented |
DL0004 # 05 Y:2007 | 05 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,506 | $33,000 | Not Implemented |
DL0004 # 06 Y:2007 | 06 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $93,700 | $130,000 | Not Implemented |
DL0004 # 07 Y:2007 | 07 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,203 | $8,830 | Not Implemented |
NC0354 # 01 Y:2007 | 01 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $39,874 | $45,600 | Not Implemented |
NC0354 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $32,774 | $100,000 | Not Implemented |
NC0354 # 03 Y:2007 | 03 | 2007 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $65,972 | $100,000 | Not Implemented |