Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,716
matching recommendationsNAICS | 337 | Furniture and Related Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0174 # 08 Y:2015 | 08 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,185 | $0 | Not Implemented |
IP0037 # 01 Y:2015 | 01 | 2015 | APPLY FOR INVESTMENT INCENTIVES | $2,707 | $0 | Implemented |
IP0037 # 02 Y:2015 | 02 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $267 | $0 | Not Implemented |
IP0037 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $14,074 | $227 | Implemented |
IP0037 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,417 | $113 | Implemented |
IP0037 # 05 Y:2015 | 05 | 2015 | $1,364 | $171 | Not Implemented | |
IP0037 # 06 Y:2015 | 06 | 2015 | INSULATE BARE EQUIPMENT | $1,469 | $211 | Not Implemented |
IP0037 # 07 Y:2015 | 07 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,192 | $980 | Not Implemented |
IP0037 # 08 Y:2015 | 08 | 2015 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $32,642 | $7,996 | Implemented |
IP0037 # 09 Y:2015 | 09 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,490 | $1,421 | Not Implemented |
IP0037 # 10 Y:2015 | 10 | 2015 | INSTALL OCCUPANCY SENSORS | $518 | $739 | Not Implemented |
IP0037 # 11 Y:2015 | 11 | 2015 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $12,533 | $21,055 | Implemented |
IP0037 # 12 Y:2015 | 12 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,962 | $9,239 | Not Implemented |
CO0702 # 01 Y:2015 | 01 | 2015 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $7,850 | $20,000 | n/a |
CO0702 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,630 | $950 | n/a |
CO0702 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,680 | $42,100 | n/a |
CO0702 # 04 Y:2015 | 04 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,480 | $500 | n/a |
NC0533 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,228 | $6,494 | Implemented |
NC0533 # 02 Y:2015 | 02 | 2015 | USE PHOTOCELL CONTROLS | $253 | $600 | Implemented |
NC0533 # 03 Y:2015 | 03 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $567 | $100 | Not Implemented |
NC0533 # 04 Y:2015 | 04 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $751 | $3,000 | Not Implemented |
NC0533 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $384 | $100 | Implemented |
NC0533 # 06 Y:2015 | 06 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $254 | $450 | Implemented |
NC0533 # 07 Y:2015 | 07 | 2015 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $571 | $2,500 | Not Implemented |
UA0129 # 01 Y:2014 | 01 | 2014 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $72,413 | $8,000 | Not Implemented |