Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
183
matching recommendationsNAICS | 339 | Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0821 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $479 | $893 | Implemented |
UD0771 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,208 | $22,275 | Not Implemented |
UD0771 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,342 | $600 | Not Implemented |
UD0771 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,341 | $7,780 | Not Implemented |
UD0771 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,639 | $8,838 | Not Implemented |
UD0771 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,830 | $10,000 | Not Implemented |
UD0771 # 06 Y:2007 | 06 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,180 | $0 | Implemented |
UD0771 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,102 | $3,285 | Not Implemented |
UD0771 # 08 Y:2007 | 08 | 2007 | INSULATE BARE EQUIPMENT | $1,182 | $1,450 | Not Implemented |
UD0771 # 09 Y:2007 | 09 | 2007 | DISCONNECT BALLASTS | $304 | $0 | Implemented |
UD0768 # 09 Y:2007 | 09 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $860 | $0 | Implemented |
UD0768 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,680 | $80,800 | Not Implemented |
UD0768 # 06 Y:2007 | 06 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,131 | $1,000 | Not Implemented |
UD0768 # 07 Y:2007 | 07 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $2,180 | $0 | Implemented |
UD0768 # 08 Y:2007 | 08 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $1,410 | $400 | Not Implemented |
UD0768 # 05 Y:2007 | 05 | 2007 | REPLACE BOILER | $5,791 | $40,000 | Not Implemented |
UD0768 # 04 Y:2007 | 04 | 2007 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $8,081 | $4,600 | Not Implemented |
UD0768 # 03 Y:2007 | 03 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $10,780 | $20,512 | Not Implemented |
UD0768 # 02 Y:2007 | 02 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,440 | $46,362 | Not Implemented |
WV0360 # 07 Y:2007 | 07 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,158 | $400 | Not Implemented |
WV0360 # 01 Y:2007 | 01 | 2007 | ADJUST BURNERS FOR EFFICIENT OPERATION | $48,535 | $170,000 | Not Implemented |
WV0360 # 09 Y:2007 | 09 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,188 | $25 | Implemented |
WV0360 # 11 Y:2007 | 11 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,426 | $900 | Implemented |
WV0360 # 10 Y:2007 | 10 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,930 | $300 | Implemented |
WV0360 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,939 | $70,000 | Not Implemented |