Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
891
matching recommendationsNAICS | 33999 | All Other Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0016 # 04 Y:2008 | 04 | 2008 | INSTALL OCCUPANCY SENSORS | $3,343 | $590 | Implemented |
DL0016 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,304 | $500 | Not Implemented |
DL0016 # 06 Y:2008 | 06 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $635 | $160 | Not Implemented |
DL0016 # 07 Y:2008 | 07 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $24 | $2,394 | Implemented |
DL0016 # 08 Y:2008 | 08 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $38,540 | $125,000 | Not Implemented |
DL0016 # 09 Y:2008 | 09 | 2008 | USE SOLAR HEAT TO MAKE ELECTRICTY | $15,600 | $600,000 | Not Implemented |
LL0294 # 01 Y:2008 | 01 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $31,560 | $45,800 | Not Implemented |
LL0294 # 02 Y:2008 | 02 | 2008 | OPTIMIZE PLANT POWER FACTOR | $16,326 | $5,201 | Not Implemented |
LL0294 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,541 | $10,640 | Not Implemented |
LL0294 # 04 Y:2008 | 04 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,897 | $1,210 | Implemented |
LL0294 # 05 Y:2008 | 05 | 2008 | INSULATE BARE EQUIPMENT | $4,740 | $2,539 | Not Implemented |
LL0294 # 06 Y:2008 | 06 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,006 | $1,880 | Not Implemented |
LL0294 # 07 Y:2008 | 07 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,841 | $210 | Not Implemented |
LL0294 # 08 Y:2008 | 08 | 2008 | INSTALL OCCUPANCY SENSORS | $645 | $90 | Implemented |
LL0294 # 09 Y:2008 | 09 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $527 | $350 | Not Implemented |
TT0016 # 01 Y:2008 | 01 | 2008 | OPTIMIZE PLANT POWER FACTOR | $17,400 | $50,000 | Implemented |
TT0016 # 02 Y:2008 | 02 | 2008 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $5,929 | $1,500 | Not Implemented |
TT0016 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,553 | $42,900 | Implemented |
TT0016 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $19,000 | $19,750 | Not Implemented |
UD0771 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,208 | $22,275 | Not Implemented |
UD0771 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,342 | $600 | Not Implemented |
UD0771 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,341 | $7,780 | Not Implemented |
UD0771 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,639 | $8,838 | Not Implemented |
UD0771 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,830 | $10,000 | Not Implemented |
UD0771 # 06 Y:2007 | 06 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,180 | $0 | Implemented |