Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,728
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0114 # 04 Y:2001 | 04 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,376 | $0 | Implemented |
LE0114 # 06 Y:2001 | 06 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,207 | $2,500 | Implemented |
LE0114 # 07 Y:2001 | 07 | 2001 | TREAT AND REUSE RINSE WATERS | $753 | $3,750 | Implemented |
WV0215 # 01 Y:2001 | 01 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $406 | $52 | Implemented |
WV0215 # 02 Y:2001 | 02 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $93 | $300 | Implemented |
WV0215 # 05 Y:2001 | 05 | 2001 | USE OPTIMUM THICKNESS INSULATION | $1,387 | $585 | Implemented |
WV0215 # 08 Y:2001 | 08 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $97 | $780 | Implemented |
WV0215 # 09 Y:2001 | 09 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $3,456 | $100 | Implemented |
WV0215 # 10 Y:2001 | 10 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,440 | $100 | Implemented |
MI0010 # 01 Y:2001 | 01 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $2,160 | $1,009 | Implemented |
MI0010 # 02 Y:2001 | 02 | 2001 | METER WASTE WATER | $3,711 | $3,650 | Implemented |
MI0010 # 03 Y:2001 | 03 | 2001 | IMPROVE SPACE COMFORT CONDITIONING | $47,345 | $7,000 | Implemented |
MI0010 # 04 Y:2001 | 04 | 2001 | INSTALL SPECTRAL REFLECTORS / DELAMP | $8,000 | $5,000 | Implemented |
SF0219 # 06 Y:2001 | 06 | 2001 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $14,216 | $507 | Implemented |
SF0219 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,206 | $0 | Implemented |
SF0219 # 02 Y:2001 | 02 | 2001 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $5,816 | $5,705 | Implemented |
SF0219 # 03 Y:2001 | 03 | 2001 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $415 | $406 | Implemented |
SF0219 # 04 Y:2001 | 04 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $529 | $840 | Implemented |
CO0483 # 01 Y:2001 | 01 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,160 | $0 | Implemented |
CO0483 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $90 | $0 | Implemented |
CO0483 # 04 Y:2001 | 04 | 2001 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $4,810 | $4,730 | Implemented |
SF0217 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,715 | $0 | Implemented |
SF0217 # 02 Y:2001 | 02 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $611 | $0 | Implemented |
SF0217 # 03 Y:2001 | 03 | 2001 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $2,551 | $248 | Implemented |
SF0217 # 04 Y:2001 | 04 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,181 | $3,150 | Implemented |