Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,785
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0995 # 05 Y:2019 | 05 | 2019 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $110,256 | $150,000 | Not Implemented |
UD0995 # 06 Y:2019 | 06 | 2019 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $35,713 | $75,000 | Not Implemented |
UD0995 # 07 Y:2019 | 07 | 2019 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,847 | $11,694 | Implemented |
UD0995 # 08 Y:2019 | 08 | 2019 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $606 | $0 | Implemented |
UD0995 # 09 Y:2019 | 09 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,887 | $17,856 | Implemented |
SU0475 # 01 Y:2019 | 01 | 2019 | PAY BILLS ON TIME TO AVOID LATE FEES | $388 | $0 | Implemented |
SU0475 # 02 Y:2019 | 02 | 2019 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $201 | $100 | Not Implemented |
SU0475 # 03 Y:2019 | 03 | 2019 | ELIMINATE/REDUCE AN OPERATION | $10,247 | $7,500 | Not Implemented |
SU0475 # 04 Y:2019 | 04 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,189 | $1,231 | Not Implemented |
SU0475 # 05 Y:2019 | 05 | 2019 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $136 | $195 | Not Implemented |
SU0475 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,279 | $7,474 | Not Implemented |
UU0147 # 01 Y:2019 | 01 | 2019 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $54,000 | $300,000 | Not Implemented |
UU0147 # 02 Y:2019 | 02 | 2019 | USE OPTIMUM THICKNESS INSULATION | $3,521 | $2,917 | Implemented |
UU0147 # 03 Y:2019 | 03 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,684 | $7,000 | Implemented |
UU0147 # 04 Y:2019 | 04 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,746 | $1,200 | Implemented |
UU0147 # 05 Y:2019 | 05 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,081 | $1,800 | Implemented |
UU0147 # 06 Y:2019 | 06 | 2019 | TURN OFF EQUIPMENT WHEN NOT IN USE | $130 | $0 | Implemented |
UU0147 # 07 Y:2019 | 07 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $433 | $400 | Implemented |
UU0146 # 01 Y:2019 | 01 | 2019 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $37,500 | $225,000 | Not Implemented |
UU0146 # 02 Y:2019 | 02 | 2019 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,186 | $2,000 | Not Implemented |
UU0146 # 03 Y:2019 | 03 | 2019 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,780 | $0 | Implemented |
UU0146 # 04 Y:2019 | 04 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,035 | $350 | Not Implemented |
UU0146 # 05 Y:2019 | 05 | 2019 | INSTALL / REPAIR INSULATION ON STEAM LINES | $850 | $0 | Not Implemented |
UU0146 # 06 Y:2019 | 06 | 2019 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $693 | $2,575 | Not Implemented |
UU0146 # 07 Y:2019 | 07 | 2019 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $367 | $1,200 | Not Implemented |