IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

825

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0181 # 02 Y:1985 02 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,120 $6,500 Not Implemented
OK0181 # 03 Y:1985 03 1985 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $3,832 $2,940 Not Implemented
OK0181 # 04 Y:1985 04 1985 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $1,131 $579 Not Implemented
OK0181 # 05 Y:1985 05 1985 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $649 $592 Implemented
OK0181 # 06 Y:1985 06 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,428 $57 Implemented
OK0166 # 01 Y:1985 01 1985 ELIMINATE LEAKS IN WATER LINES AND VALVES $3,054 $850 Not Implemented
OK0166 # 02 Y:1985 02 1985 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $34,175 $6,260 Not Implemented
OK0166 # 03 Y:1985 03 1985 INSULATE BARE EQUIPMENT $5,377 $2,398 Implemented
OK0166 # 04 Y:1985 04 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,074 $403 Not Implemented
OK0166 # 05 Y:1985 05 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $7,782 $30,000 Not Implemented
OK0166 # 06 Y:1985 06 1985 INSULATE BARE EQUIPMENT $950 $624 Implemented
OK0149 # 01 Y:1984 01 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $363 $650 Implemented
OK0149 # 02 Y:1984 02 1984 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,221 $2,000 Not Implemented
OK0149 # 03 Y:1984 03 1984 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $351 $220 Implemented
OK0149 # 04 Y:1984 04 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $625 $1,700 Implemented
OK0149 # 05 Y:1984 05 1984 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $360 $104 Implemented
OK0149 # 06 Y:1984 06 1984 INSTALL / REPAIR INSULATION ON STEAM LINES $3,556 $785 Implemented
OK0149 # 07 Y:1984 07 1984 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $126 $235 Implemented
OK0149 # 08 Y:1984 08 1984 INSULATE BARE EQUIPMENT $155 $235 Implemented
OK0149 # 09 Y:1984 09 1984 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $826 $0 Implemented
OK0149 # 10 Y:1984 10 1984 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,537 $480 Implemented
OK0137 # 01 Y:1984 01 1984 REPLACE GASOLINE WITH DIESEL, LPG, OR NATURAL GAS $121,449 $176,369 Not Implemented
OK0137 # 02 Y:1984 02 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $135 $125 Implemented
OK0137 # 03 Y:1984 03 1984 INSTALL TIMERS AND/OR THERMOSTATS $140 $350 Implemented
OK0137 # 04 Y:1984 04 1984 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $363 $0 Implemented