IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,699

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0304 # 07 Y:1997 07 1997 REPAIR AND ELIMINATE STEAM LEAKS $190 $65 Implemented
AM0304 # 08 Y:1997 08 1997 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $115 $0 Implemented
AM0304 # 09 Y:1997 09 1997 DISCONNECT BALLASTS $110 $10 Implemented
UM0092 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,141 $4,497 Not Implemented
UM0092 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,616 $29,553 Not Implemented
UM0092 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $696 $1,000 Not Implemented
UM0092 # 04 Y:1997 04 1997 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $35,249 $8,500 Not Implemented
UM0092 # 05 Y:1997 05 1997 INSULATE BARE EQUIPMENT $1,392 $5,361 Not Implemented
UM0092 # 06 Y:1997 06 1997 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $245,000 $10,000 Not Implemented
UM0092 # 07 Y:1997 07 1997 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $4,512 $300 Not Implemented
IA0171 # 01 Y:1997 01 1997 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $13,500 $25,100 Not Implemented
IA0171 # 02 Y:1997 02 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,701 $4,500 Not Implemented
IA0171 # 03 Y:1997 03 1997 DIRECT WARMEST AIR TO COMBUSTION INTAKE $3,600 $1,720 Not Implemented
IA0171 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,164 $1,652 Not Implemented
IA0171 # 05 Y:1997 05 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $374 $684 Not Implemented
UF0184 # 01 Y:1997 01 1997 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,816 $15,515 Not Implemented
UF0184 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $252 $252 Implemented
UF0184 # 03 Y:1997 03 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,782 $1,000 Implemented
UF0184 # 04 Y:1997 04 1997 INSTALL / REPAIR INSULATION ON STEAM LINES $2,851 $451 Implemented
UF0184 # 05 Y:1997 05 1997 INSULATE BARE EQUIPMENT $1,170 $974 Implemented
UF0184 # 06 Y:1997 06 1997 INSULATE FEEDWATER TANK $1,304 $200 Implemented
UF0184 # 07 Y:1997 07 1997 ELIMINATE PRACTICE OF MIXING WASTE STREAMS $1,261 $5,000 Not Implemented
UF0184 # 08 Y:1997 08 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $3,613 $0 Not Implemented
UF0184 # 09 Y:1997 09 1997 PURCHASE MATERIAL FROM SUPPLIER IN CUSTOMIZED PACKAGING $4,655 $1,800 Not Implemented
UF0184 # 10 Y:1997 10 1997 PURCHASE EQUIPMENT INSTEAD OF LEASING $12,450 $15,000 Implemented