Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,647
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0311 # 06 Y:2005 | 06 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,803 | $2,959 | Not Implemented |
SF0311 # 07 Y:2005 | 07 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,363 | $6,375 | Implemented |
SF0311 # 08 Y:2005 | 08 | 2005 | USE PHOTOCELL CONTROLS | $412 | $480 | Not Implemented |
SF0311 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,804 | $2,332 | Not Implemented |
SF0311 # 10 Y:2005 | 10 | 2005 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $3,402 | $5,030 | Not Implemented |
SF0311 # 11 Y:2005 | 11 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $456 | $693 | Not Implemented |
SF0311 # 12 Y:2005 | 12 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,102 | $18,405 | Not Implemented |
SF0311 # 13 Y:2005 | 13 | 2005 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $345 | $658 | Not Implemented |
SF0311 # 14 Y:2005 | 14 | 2005 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $22,029 | $46,851 | Not Implemented |
SF0311 # 15 Y:2005 | 15 | 2005 | MODIFY STARTUP/SHUTDOWN TIMES | $3,118 | $13,200 | Not Implemented |
SF0311 # 16 Y:2005 | 16 | 2005 | ELIMINATE/REDUCE AN OPERATION | $1,600 | $0 | Not Implemented |
SF0311 # 17 Y:2005 | 17 | 2005 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $19,680 | $12,330 | Implemented |
SF0310 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,347 | $480 | Not Implemented |
SF0310 # 02 Y:2005 | 02 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $728 | $120 | Not Implemented |
SF0310 # 03 Y:2005 | 03 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,633 | $3,457 | Not Implemented |
SF0310 # 04 Y:2005 | 04 | 2005 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,150 | $2,900 | Not Implemented |
SF0310 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $1,456 | $1,635 | Not Implemented |
SF0310 # 06 Y:2005 | 06 | 2005 | INSULATE BARE EQUIPMENT | $1,570 | $1,687 | Not Implemented |
SF0310 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,218 | $24,484 | Not Implemented |
SF0310 # 08 Y:2005 | 08 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $6,777 | $18,995 | Not Implemented |
SF0310 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,603 | $14,240 | Not Implemented |
SF0310 # 10 Y:2005 | 10 | 2005 | USE DECANTING, FLOTATION TO REMOVE CONTAMINANTS | $38,197 | $66,900 | Not Implemented |
SD0368 # 01 Y:2005 | 01 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $85,079 | $99,260 | Not Implemented |
SD0368 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $82,308 | $130,000 | Not Implemented |
SD0368 # 03 Y:2005 | 03 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $49,689 | $30,500 | Not Implemented |