Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,647

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0167 # 09 Y:1999 09 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,353 $30,890 Not Implemented
NV0128 # 01 Y:1999 01 1999 INSULATE BARE EQUIPMENT $21,114 $38,248 Implemented
NV0128 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $67,624 $122,252 Not Implemented
NV0128 # 03 Y:1999 03 1999 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $45,418 $62,000 Not Implemented
NV0128 # 04 Y:1999 04 1999 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $129,730 $188,500 Not Implemented
SD0222 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,813 $4,697 Implemented
SD0222 # 02 Y:1999 02 1999 INSTALL SPECTRAL REFLECTORS / DELAMP $1,888 $2,790 Not Implemented
SD0222 # 03 Y:1999 03 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,584 $6,000 Not Implemented
SD0222 # 04 Y:1999 04 1999 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,823 $19,600 Not Implemented
SD0222 # 05 Y:1999 05 1999 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $7,799 $11,000 Not Implemented
SD0222 # 06 Y:1999 06 1999 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $24,876 $14,300 Not Implemented
SD0222 # 07 Y:1999 07 1999 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $10,400 $10,000 Not Implemented
SF0154 # 01 Y:1998 01 1998 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $3,242 $0 Implemented
SF0154 # 02 Y:1998 02 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $112,256 $73,966 Not Implemented
SF0154 # 03 Y:1998 03 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,646 $4,900 Implemented
SF0154 # 04 Y:1998 04 1998 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $15,577 $17,000 Not Implemented
SF0154 # 05 Y:1998 05 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $12,270 $17,928 Not Implemented
SF0154 # 06 Y:1998 06 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,837 $5,310 Not Implemented
SF0154 # 07 Y:1998 07 1998 INCREASE AMOUNT OF CONDENSATE RETURNED $3,288 $6,477 Not Implemented
SF0154 # 08 Y:1998 08 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,681 $9,290 Implemented
SF0154 # 09 Y:1998 09 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,664 $4,281 Implemented
SF0154 # 10 Y:1998 10 1998 USE PHOTOCELL CONTROLS $1,549 $9,500 Implemented
SF0154 # 11 Y:1998 11 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,965 $24,395 Not Implemented
SF0153 # 01 Y:1998 01 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,127 $50 Not Implemented
SF0153 # 02 Y:1998 02 1998 REPAIR AND ELIMINATE STEAM LEAKS $1,107 $1,250 Not Implemented