Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
39
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0404 # 05 Y:1997 | 05 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $200 | $0 | Implemented |
CO0404 # 01 Y:1997 | 01 | 1997 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,800 | $5,000 | Implemented |
CO0404 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,420 | $280 | Implemented |
CO0404 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $365 | $498 | Implemented |
CO0404 # 04 Y:1997 | 04 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $210 | $440 | Implemented |
CO0403 # 04 Y:1997 | 04 | 1997 | REPAIR AND ELIMINATE STEAM LEAKS | $380 | $300 | Not Implemented |
CO0403 # 02 Y:1997 | 02 | 1997 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $1,790 | $2,000 | Not Implemented |
CO0403 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,072 | $6,685 | Not Implemented |
CO0403 # 03 Y:1997 | 03 | 1997 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,180 | $0 | Not Implemented |
CO0403 # 05 Y:1997 | 05 | 1997 | INSTALL / REPAIR INSULATION ON STEAM LINES | $280 | $810 | Not Implemented |
CO0403 # 06 Y:1997 | 06 | 1997 | $3,120 | $0 | Not Implemented | |
CO0395 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $920 | $-3,940 | Implemented |
CO0395 # 02 Y:1997 | 02 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $630 | $930 | Implemented |
CO0395 # 03 Y:1997 | 03 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $56,440 | $245,000 | Not Implemented |
CO0387 # 01 Y:1997 | 01 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,360 | $8,400 | Implemented |
CO0387 # 02 Y:1997 | 02 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,130 | $1,500 | Implemented |
CO0387 # 03 Y:1997 | 03 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $289 | $288 | Implemented |
CO0387 # 04 Y:1997 | 04 | 1997 | REPAIR AND ELIMINATE STEAM LEAKS | $670 | $140 | Implemented |
CO0387 # 05 Y:1997 | 05 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $380 | $430 | Implemented |
CO0387 # 06 Y:1997 | 06 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $220 | $290 | Implemented |
CO0387 # 07 Y:1997 | 07 | 1997 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $18,030 | $4,000 | Implemented |
CO0387 # 08 Y:1997 | 08 | 1997 | $33,500 | $90,000 | Implemented | |
CO0387 # 09 Y:1997 | 09 | 1997 | $15,600 | $21,000 | Implemented | |
CO0382 # 01 Y:1997 | 01 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,200 | $1,700 | Implemented |
CO0382 # 08 Y:1997 | 08 | 1997 | SELL / OFFER BY-PRODUCT AS ANIMAL FEED | $1,430 | $5,000 | Implemented |