Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
781
matching recommendationsSIC | 2011 | Meat Packing Plants |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NL0039 # 04 Y:2019 | 04 | 2019 | MINIMIZE WATER USAGE | $10,832 | $1,127 | Implemented |
NL0039 # 03 Y:2019 | 03 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,128 | $2,497 | Implemented |
NL0039 # 02 Y:2019 | 02 | 2019 | REPAIR OR REPLACE STEAM TRAPS | $15,324 | $44 | Implemented |
NL0039 # 01 Y:2019 | 01 | 2019 | OPTIMIZE PLANT POWER FACTOR | $36,367 | $39,000 | Implemented |
IC0218 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,997 | $8,799 | Not Implemented |
IC0218 # 02 Y:2019 | 02 | 2019 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $63,690 | $6,300 | Not Implemented |
IC0218 # 03 Y:2019 | 03 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,151 | $14,700 | Not Implemented |
IC0218 # 04 Y:2019 | 04 | 2019 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,883 | $8,244 | Not Implemented |
IP0108 # 12 Y:2018 | 12 | 2018 | OPTIMIZE PLANT POWER FACTOR | $864 | $4,146 | Not Implemented |
IP0108 # 11 Y:2018 | 11 | 2018 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $352 | $1,323 | Not Implemented |
IP0108 # 10 Y:2018 | 10 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,909 | $19,975 | Not Implemented |
IP0108 # 09 Y:2018 | 09 | 2018 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,070 | $2,129 | Not Implemented |
IP0108 # 08 Y:2018 | 08 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $685 | $1,022 | Not Implemented |
IP0108 # 07 Y:2018 | 07 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $115 | $53 | Not Implemented |
IP0108 # 06 Y:2018 | 06 | 2018 | USE SOLAR HEAT TO MAKE ELECTRICTY | $6,000 | $3,479 | Not Implemented |
IP0108 # 05 Y:2018 | 05 | 2018 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,465 | $322 | Not Implemented |
IP0108 # 04 Y:2018 | 04 | 2018 | INSTALL OCCUPANCY SENSORS | $2,230 | $339 | Not Implemented |
IP0108 # 03 Y:2018 | 03 | 2018 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $12,119 | $600 | Not Implemented |
IP0108 # 01 Y:2018 | 01 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,011 | $0 | Not Implemented |
IP0108 # 02 Y:2018 | 02 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $880 | $4 | Not Implemented |
AM0749 # 01 Y:2018 | 01 | 2018 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $136,440 | $167,100 | Not Implemented |
AM0749 # 02 Y:2018 | 02 | 2018 | COMBINE UTILITY METERS | $65,915 | $10,000 | Not Implemented |
AM0749 # 03 Y:2018 | 03 | 2018 | OPTIMIZE PLANT POWER FACTOR | $31,797 | $45,252 | Not Implemented |
AM0749 # 04 Y:2018 | 04 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,000 | $15,400 | Not Implemented |
AM0749 # 05 Y:2018 | 05 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,165 | $40 | Not Implemented |