Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,313
matching recommendationsSIC | 202 | Dairy Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DS0067 # 04 Y:1996 | 04 | 1996 | OPTIMIZE PLANT POWER FACTOR | $9,685 | $6,735 | Implemented |
DS0067 # 05 Y:1996 | 05 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $7,027 | $2,390 | Implemented |
AS0190 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,769 | $100 | Implemented |
AS0190 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,298 | $440 | Implemented |
AS0190 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $2,310 | $2,025 | Implemented |
AS0190 # 04 Y:1996 | 04 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,913 | $5,700 | Implemented |
AS0190 # 06 Y:1996 | 06 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $190,648 | $100,000 | Implemented |
AS0190 # 08 Y:1996 | 08 | 1996 | MINIMIZE WATER USAGE | $10,501 | $200 | Implemented |
IA0153 # 01 Y:1996 | 01 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $8,102 | $2,678 | Implemented |
IA0153 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,805 | $4,646 | Implemented |
IA0153 # 04 Y:1996 | 04 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,758 | $2,000 | Implemented |
IA0153 # 07 Y:1996 | 07 | 1996 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $2,570 | $250 | Implemented |
IA0153 # 11 Y:1996 | 11 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $243 | $250 | Implemented |
ME0197 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,551 | $9,015 | Implemented |
ME0197 # 02 Y:1996 | 02 | 1996 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $963 | $0 | Implemented |
ME0197 # 03 Y:1996 | 03 | 1996 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $7,463 | $6,000 | Implemented |
ME0197 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $3,628 | $600 | Implemented |
ME0197 # 05 Y:1996 | 05 | 1996 | MINIMIZE WATER USAGE | $2,684 | $400 | Implemented |
ME0197 # 06 Y:1996 | 06 | 1996 | MINIMIZE WATER USAGE | $665 | $0 | Implemented |
HO0129 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,789 | $10,234 | Implemented |
HO0129 # 02 Y:1996 | 02 | 1996 | INSTALL OCCUPANCY SENSORS | $713 | $400 | Implemented |
HO0129 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $246 | $292 | Implemented |
HO0129 # 05 Y:1996 | 05 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,150 | $2,200 | Implemented |
HO0129 # 06 Y:1996 | 06 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $11,191 | $20,000 | Implemented |
ME0180 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,951 | $17,121 | Implemented |