Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

276

matching recommendations
Reset
SIC 202 Dairy Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0310 # 08 Y:2005 08 2005 UPGRADE CONTROLS ON COMPRESSORS $6,777 $18,995 Not Implemented
SF0310 # 09 Y:2005 09 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,603 $14,240 Not Implemented
SF0310 # 10 Y:2005 10 2005 USE DECANTING, FLOTATION TO REMOVE CONTAMINANTS $38,197 $66,900 Not Implemented
SF0275 # 01 Y:2004 01 2004 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,063 $739 Not Implemented
SF0275 # 02 Y:2004 02 2004 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $49,562 $39,000 Implemented
SF0275 # 03 Y:2004 03 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,238 $0 Implemented
SF0275 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,909 $3,688 Implemented
SF0275 # 05 Y:2004 05 2004 COVER OPEN TANKS $715 $1,469 Not Implemented
SF0275 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,604 $12,835 Not Implemented
SF0275 # 07 Y:2004 07 2004 INSTALL OCCUPANCY SENSORS $1,197 $4,096 Not Implemented
SF0275 # 08 Y:2004 08 2004 USE PHOTOCELL CONTROLS $613 $2,971 Not Implemented
SF0275 # 09 Y:2004 09 2004 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $30,592 $34,814 Not Implemented
SF0269 # 01 Y:2003 01 2003 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $5,192 $0 Not Implemented
SF0269 # 02 Y:2003 02 2003 IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS $635 $0 Implemented
SF0269 # 03 Y:2003 03 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,974 $0 Not Implemented
SF0269 # 04 Y:2003 04 2003 INSULATE BARE EQUIPMENT $5,516 $3,984 Not Implemented
SF0269 # 05 Y:2003 05 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,653 $0 Implemented
SF0269 # 06 Y:2003 06 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,739 $3,905 Not Implemented
SF0269 # 07 Y:2003 07 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $633 $1,743 Not Implemented
SD0308 # 01 Y:2002 01 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $168,158 $56,000 Not Implemented
SD0308 # 02 Y:2002 02 2002 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $7,470 $6,000 Not Implemented
SD0308 # 03 Y:2002 03 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,224 $5,000 Not Implemented
SD0308 # 04 Y:2002 04 2002 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $1,853 $0 Not Implemented
SD0308 # 05 Y:2002 05 2002 USE PHOTOCELL CONTROLS $525 $500 Not Implemented
SD0308 # 06 Y:2002 06 2002 INCREASE USE OF AUTOMATION $91,000 $75,000 Not Implemented