Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
512
matching recommendationsSIC | 2024 | Ice Cream And Frozen Desserts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0057 # 04 Y:2004 | 04 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,240 | $6,450 | Not Implemented |
UU0057 # 05 Y:2004 | 05 | 2004 | INCREASE AMOUNT OF CONDENSATE RETURNED | $4,493 | $25,000 | Not Implemented |
UU0057 # 06 Y:2004 | 06 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,110 | $2,000 | Not Implemented |
UU0057 # 07 Y:2004 | 07 | 2004 | INSTALL TURBULATORS | $1,680 | $1,747 | Not Implemented |
UU0057 # 08 Y:2004 | 08 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,320 | $809 | Not Implemented |
UU0057 # 09 Y:2004 | 09 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,920 | $0 | Implemented |
UU0057 # 10 Y:2004 | 10 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $398 | $20 | Implemented |
UU0057 # 11 Y:2004 | 11 | 2004 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $25,500 | $192,450 | Not Implemented |
UU0040 # 01 Y:2003 | 01 | 2003 | OPTIMIZE PLANT POWER FACTOR | $1 | $0 | Not Implemented |
UU0040 # 02 Y:2003 | 02 | 2003 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $150 | $0 | Not Implemented |
UU0040 # 03 Y:2003 | 03 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,957 | $0 | Not Implemented |
UU0040 # 04 Y:2003 | 04 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,285 | $0 | Not Implemented |
UU0040 # 05 Y:2003 | 05 | 2003 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1 | $0 | Not Implemented |
UU0040 # 06 Y:2003 | 06 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $57 | $55 | Not Implemented |
OR0414 # 01 Y:2002 | 01 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $657,000 | $300,000 | Not Implemented |
OR0414 # 02 Y:2002 | 02 | 2002 | INSTALL AUTOMATIC PACKING EQUIPMENT | $124,333 | $56,075 | Not Implemented |
OR0414 # 03 Y:2002 | 03 | 2002 | INSTALL AUTOMATIC PACKING EQUIPMENT | $6,650 | $9,075 | Implemented |
OR0414 # 04 Y:2002 | 04 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $852 | $0 | Implemented |
OR0414 # 05 Y:2002 | 05 | 2002 | OPTIMIZE PLANT POWER FACTOR | $960 | $2,700 | Not Implemented |
WV0244 # 01 Y:2002 | 01 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,136 | $108 | Implemented |
WV0244 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $19,433 | $900 | Implemented |
WV0244 # 03 Y:2002 | 03 | 2002 | INSULATE BARE EQUIPMENT | $1,318 | $193 | Implemented |
WV0244 # 04 Y:2002 | 04 | 2002 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,380 | $4,950 | Not Implemented |
WV0244 # 05 Y:2002 | 05 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,244 | $19,144 | Not Implemented |
WV0244 # 06 Y:2002 | 06 | 2002 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $9,994 | $10,000 | Not Implemented |