Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,930
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0467 # 02 Y:2004 | 02 | 2004 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $27,150 | $252,000 | Not Implemented |
OR0467 # 03 Y:2004 | 03 | 2004 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,000 | $31,500 | Implemented |
OR0467 # 04 Y:2004 | 04 | 2004 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $46,000 | $25,000 | Not Implemented |
LL0199 # 01 Y:2004 | 01 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $33,535 | $960 | Implemented |
LL0199 # 02 Y:2004 | 02 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $25,020 | $2,910 | Implemented |
LL0199 # 03 Y:2004 | 03 | 2004 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $13,735 | $304 | Implemented |
LL0199 # 04 Y:2004 | 04 | 2004 | OPTIMIZE PLANT POWER FACTOR | $4,382 | $24,514 | Not Implemented |
LL0199 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,985 | $720 | Implemented |
LL0199 # 06 Y:2004 | 06 | 2004 | USE PHOTOCELL CONTROLS | $935 | $525 | Implemented |
LL0199 # 07 Y:2004 | 07 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $544 | $585 | Implemented |
LL0199 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $292 | $120 | Implemented |
LL0199 # 09 Y:2004 | 09 | 2004 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $41,244 | $0 | Implemented |
LL0199 # 10 Y:2004 | 10 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $4,740 | $5,697 | Implemented |
OR0459 # 01 Y:2004 | 01 | 2004 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $4,500 | $10,500 | Not Implemented |
OR0459 # 02 Y:2004 | 02 | 2004 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $9,750 | $300 | Implemented |
OR0459 # 03 Y:2004 | 03 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $4,820 | $36,600 | Implemented |
OR0459 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $34,250 | $2,000 | Implemented |
OR0459 # 05 Y:2004 | 05 | 2004 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $5,330 | $2,825 | Implemented |
OR0459 # 06 Y:2004 | 06 | 2004 | OPTIMIZE PLANT POWER FACTOR | $2,730 | $5,130 | Implemented |
LE0193 # 01 Y:2004 | 01 | 2004 | CONVERT COMBUSTION EQUIPMENT TO BURN OIL | $192,339 | $50,000 | n/a |
LE0193 # 02 Y:2004 | 02 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $105,726 | $58,053 | n/a |
LE0193 # 03 Y:2004 | 03 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $17,227 | $492 | Implemented |
LE0193 # 04 Y:2004 | 04 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,446 | $2,000 | Implemented |
LE0193 # 05 Y:2004 | 05 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,252 | $10,720 | Not Implemented |
LE0193 # 06 Y:2004 | 06 | 2004 | INSULATE FEEDWATER TANK | $11,953 | $4,508 | Implemented |