Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,904
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0311 # 02 Y:1998 | 02 | 1998 | USE OPTIMUM THICKNESS INSULATION | $1,740 | $4,421 | Not Implemented |
OR0311 # 03 Y:1998 | 03 | 1998 | OPTIMIZE PLANT POWER FACTOR | $8,062 | $21,202 | Not Implemented |
OR0311 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,341 | $20,064 | Implemented |
OR0311 # 05 Y:1998 | 05 | 1998 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,035 | $0 | Implemented |
OR0311 # 06 Y:1998 | 06 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,008 | $1,514 | Not Implemented |
OR0311 # 07 Y:1998 | 07 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $273 | $0 | Implemented |
OR0311 # 08 Y:1998 | 08 | 1998 | KEEP BOILER TUBES CLEAN | $1,431 | $1,500 | Not Implemented |
OR0311 # 09 Y:1998 | 09 | 1998 | MINIMIZE WATER USAGE | $1,020 | $0 | Not Implemented |
OR0311 # 10 Y:1998 | 10 | 1998 | MINIMIZE WATER USAGE | $275 | $0 | Not Implemented |
NV0090 # 01 Y:1997 | 01 | 1997 | INSULATE BARE EQUIPMENT | $9,086 | $58,500 | Implemented |
NV0090 # 02 Y:1997 | 02 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $124 | $0 | Implemented |
IA0185 # 01 Y:1997 | 01 | 1997 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,402 | $25 | Not Implemented |
IA0185 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,613 | $1,280 | Implemented |
IA0185 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,249 | $422 | Implemented |
IA0185 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $514 | $1,058 | Implemented |
IA0185 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $442 | $574 | Not Implemented |
ME0228 # 01 Y:1997 | 01 | 1997 | $58,961 | $46,000 | Implemented | |
ME0228 # 02 Y:1997 | 02 | 1997 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $14,209 | $23,600 | Not Implemented |
ME0228 # 03 Y:1997 | 03 | 1997 | REPAIR AND ELIMINATE STEAM LEAKS | $5,656 | $857 | Implemented |
ME0228 # 04 Y:1997 | 04 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,459 | $10,908 | Implemented |
ME0228 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,340 | $2,721 | Implemented |
ME0228 # 06 Y:1997 | 06 | 1997 | $3,664 | $0 | Implemented | |
ME0228 # 07 Y:1997 | 07 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,710 | $300 | Implemented |
ME0228 # 08 Y:1997 | 08 | 1997 | MINIMIZE WATER USAGE | $6,304 | $19,800 | Implemented |
ME0228 # 09 Y:1997 | 09 | 1997 | MINIMIZE WATER USAGE | $1,949 | $232 | Implemented |