Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
424
matching recommendationsSIC | 2035 | Pickles, Sauces, And Salad Dressings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0261 # 03 Y:1996 | 03 | 1996 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $1,824 | $4,012 | Implemented |
OR0261 # 04 Y:1996 | 04 | 1996 | OPTIMIZE PLANT POWER FACTOR | $1,181 | $4,000 | Not Implemented |
OR0261 # 05 Y:1996 | 05 | 1996 | UTILIZE OXIDATION/REDUCTION FOR NEUTRALIZATION | $92,431 | $120,000 | Implemented |
NC0052 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,358 | $2,000 | Implemented |
NC0052 # 02 Y:1995 | 02 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $403 | $100 | Implemented |
NC0052 # 03 Y:1995 | 03 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,087 | $120 | Implemented |
NC0052 # 04 Y:1995 | 04 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,703 | $15,000 | Not Implemented |
NC0052 # 05 Y:1995 | 05 | 1995 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $784 | $900 | Not Implemented |
NC0052 # 06 Y:1995 | 06 | 1995 | KEEP BOILER TUBES CLEAN | $8,880 | $0 | Implemented |
NC0052 # 07 Y:1995 | 07 | 1995 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,850 | $0 | Not Implemented |
NC0052 # 08 Y:1995 | 08 | 1995 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $71,177 | $500 | Not Implemented |
NC0052 # 09 Y:1995 | 09 | 1995 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $11,944 | $18,477 | Not Implemented |
KU0456 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,121 | $6,407 | Implemented |
KU0456 # 02 Y:1995 | 02 | 1995 | INSTALL OCCUPANCY SENSORS | $926 | $900 | Implemented |
KU0456 # 03 Y:1995 | 03 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $292 | $408 | Implemented |
KU0456 # 04 Y:1995 | 04 | 1995 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $138 | $217 | Implemented |
KU0456 # 05 Y:1995 | 05 | 1995 | INCREASE AMOUNT OF CONDENSATE RETURNED | $150 | $450 | Implemented |
KU0456 # 06 Y:1995 | 06 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,740 | $3,500 | Implemented |
CO0326 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,670 | $23,310 | Implemented |
CO0326 # 02 Y:1995 | 02 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,330 | $6,500 | Implemented |
CO0326 # 03 Y:1995 | 03 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,790 | $1,040 | Implemented |
CO0326 # 04 Y:1995 | 04 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,460 | $3,320 | Not Implemented |
CO0326 # 05 Y:1995 | 05 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,230 | $530 | Implemented |
CO0326 # 06 Y:1995 | 06 | 1995 | REPAIR AND ELIMINATE STEAM LEAKS | $460 | $160 | Implemented |
UD0450 # 01 Y:1995 | 01 | 1995 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $9,163 | $0 | Implemented |