Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
34
matching recommendationsSIC | 2051 | Bread, Cake, And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0912 # 02 Y:2015 | 02 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,191 | $8,250 | Implemented |
OK0912 # 01 Y:2015 | 01 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,007 | $1,150 | Implemented |
OK0912 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $699 | $1,752 | Implemented |
OK0912 # 06 Y:2015 | 06 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,077 | $10,897 | Implemented |
OK0912 # 08 Y:2015 | 08 | 2015 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $64 | $46 | Implemented |
OK0912 # 09 Y:2015 | 09 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,274 | $460 | Implemented |
OK0791 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $900 | $3,735 | Implemented |
OK0791 # 11 Y:2010 | 11 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,764 | $1,050 | Implemented |
OK0791 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,255 | $3,402 | Implemented |
OK0787 # 07 Y:2010 | 07 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $8,451 | $16,000 | Implemented |
OK0787 # 05 Y:2010 | 05 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $176 | $86 | Implemented |
OK0787 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,288 | $7,168 | Implemented |
OK0546 # 10 Y:1998 | 10 | 1998 | INSULATE BARE EQUIPMENT | $176 | $542 | Implemented |
OK0546 # 07 Y:1998 | 07 | 1998 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,398 | $500 | Implemented |
OK0546 # 06 Y:1998 | 06 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,273 | $2,460 | Implemented |
OK0546 # 05 Y:1998 | 05 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,438 | $5,916 | Implemented |
OK0546 # 02 Y:1998 | 02 | 1998 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $10,400 | $7,900 | Implemented |
OK0536 # 08 Y:1997 | 08 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,650 | $0 | Implemented |
OK0536 # 06 Y:1997 | 06 | 1997 | METER WASTE WATER | $75,704 | $0 | Implemented |
OK0536 # 04 Y:1997 | 04 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $365 | $0 | Implemented |
OK0527 # 08 Y:1997 | 08 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $157 | $1,080 | Implemented |
OK0527 # 07 Y:1997 | 07 | 1997 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $1,608 | $14,500 | Implemented |
OK0527 # 05 Y:1997 | 05 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,414 | $8,400 | Implemented |
OK0527 # 04 Y:1997 | 04 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $3,375 | $0 | Implemented |
OK0527 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,517 | $18,540 | Implemented |