Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

540

matching recommendations
Reset
SIC 208 Beverages
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0072 # 08 Y:1996 08 1996 INSULATE BARE EQUIPMENT $6,756 $890 Implemented
NV0072 # 09 Y:1996 09 1996 ADOPT IN-HOUSE MATERIAL GENERATION $46,800 $600 Not Implemented
NV0072 # 10 Y:1996 10 1996 ELIMINATE LEAKS IN WATER LINES AND VALVES $146 $23 Implemented
SF0030 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,894 $6,328 Implemented
SF0030 # 02 Y:1994 02 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $10,436 $25,500 Not Implemented
SF0030 # 03 Y:1994 03 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,671 $1,056 Implemented
SF0030 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,370 $6,101 Implemented
SF0030 # 05 Y:1994 05 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,504 $10,968 Not Implemented
SF0030 # 06 Y:1994 06 1994 OPTIMIZE PLANT POWER FACTOR $2,101 $2,758 Not Implemented
SF0030 # 07 Y:1994 07 1994 USE SYNTHETIC LUBRICANT $486 $0 Implemented
SF0030 # 08 Y:1994 08 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $266 $239 Implemented
SF0030 # 09 Y:1994 09 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $163 $600 Not Implemented
SD0069 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,020 $3,197 Implemented
SD0069 # 02 Y:1993 02 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,867 $8,765 Not Implemented
SD0069 # 03 Y:1993 03 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,602 $20 Implemented
SD0069 # 04 Y:1993 04 1993 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $35,110 $13,450 Not Implemented
SD0069 # 05 Y:1993 05 1993 RECOVER WASTE HEAT FROM EQUIPMENT $41,306 $65,900 Not Implemented
SD0069 # 06 Y:1993 06 1993 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $946 $983 Implemented
SD0069 # 07 Y:1993 07 1993 USE OPTIMUM THICKNESS INSULATION $381 $662 Implemented
SD0069 # 08 Y:1993 08 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $956 $0 Implemented
SD0069 # 09 Y:1993 09 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,628 $1,469 Implemented
SD0069 # 10 Y:1993 10 1993 INSTALL SPECTRAL REFLECTORS / DELAMP $4,827 $7,325 Implemented
SD0069 # 11 Y:1993 11 1993 INSTALL SET-BACK TIMERS $2,135 $3,680 Implemented
SD0069 # 12 Y:1993 12 1993 INSTALL SET-BACK TIMERS $6,228 $4,600 Implemented
SD0069 # 13 Y:1993 13 1993 INSTALL SET-BACK TIMERS $2,424 $200 Implemented