IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,383

matching recommendations
Reset
SIC 208 Beverages
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0290 # 13 Y:2004 13 2004 REUSE RICH WHITE WATER IN OTHER APPLICATIONS $16,014 $0 Not Implemented
SF0290 # 14 Y:2004 14 2004 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $22,900 $20,000 Not Implemented
SF0290 # 15 Y:2004 15 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $130,619 $218,815 Not Implemented
LE0199 # 01 Y:2004 01 2004 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $37,230 $16,000 n/a
LE0199 # 02 Y:2004 02 2004 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $9,780 $15,000 Not Implemented
LE0199 # 03 Y:2004 03 2004 INSULATE FEEDWATER TANK $8,188 $2,220 Implemented
LE0199 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,404 $300 Implemented
LE0199 # 05 Y:2004 05 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,019 $1,884 Not Implemented
NC0291 # 01 Y:2004 01 2004 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $68,169 $77,000 Not Implemented
NC0291 # 02 Y:2004 02 2004 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,122 $9,500 Implemented
NC0291 # 03 Y:2004 03 2004 SELL / OFFER BY-PRODUCT AS ANIMAL FEED $29,780 $8,900 Not Implemented
NC0291 # 04 Y:2004 04 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $412 $250 Implemented
NC0291 # 05 Y:2004 05 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $208 $100 Implemented
NC0291 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $433 $214 Implemented
UU0067 # 01 Y:2004 01 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $25,126 $0 Implemented
UU0067 # 02 Y:2004 02 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $12,160 $200 Not Implemented
UU0067 # 03 Y:2004 03 2004 REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS $495 $400 Not Implemented
UU0067 # 04 Y:2004 04 2004 INSTALL WIND POWERED ELECTRIC GENERATOR $0 $0 Implemented
UU0067 # 05 Y:2004 05 2004 INSTALL WIND POWERED ELECTRIC GENERATOR $0 $40,000 Not Implemented
UU0067 # 06 Y:2004 06 2004 TREAT AND REUSE RINSE WATERS $635,880 $1,705,000 Not Implemented
SF0288 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $220 $204 Not Implemented
SF0288 # 02 Y:2004 02 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,407 $1,649 Not Implemented
SF0288 # 03 Y:2004 03 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $481 $380 Not Implemented
SF0288 # 04 Y:2004 04 2004 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $842 $1,252 Not Implemented
SF0288 # 05 Y:2004 05 2004 INSTALL OCCUPANCY SENSORS $1,425 $2,689 Not Implemented