Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
58
matching recommendationsSIC | 2086 | Bottled And Canned Soft Drinks |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0051 # 05 Y:2010 | 05 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,963 | $0 | Not Implemented |
MZ0051 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,408 | $0 | Not Implemented |
MZ0051 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $544 | $400 | Not Implemented |
MZ0051 # 08 Y:2010 | 08 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,123 | $800 | Not Implemented |
MZ0051 # 09 Y:2010 | 09 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $32,817 | $10,000 | Not Implemented |
BD0316 # 02 Y:2006 | 02 | 2006 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $4,724 | $1,200 | Implemented |
BD0316 # 01 Y:2006 | 01 | 2006 | USE SYNTHETIC LUBRICANT | $7,871 | $800 | Not Implemented |
BD0316 # 03 Y:2006 | 03 | 2006 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $13,153 | $8,363 | Implemented |
BD0316 # 04 Y:2006 | 04 | 2006 | INSTALL OCCUPANCY SENSORS | $1,033 | $675 | Implemented |
BD0316 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $679 | $2,102 | Implemented |
KU0493 # 06 Y:1998 | 06 | 1998 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $770 | $600 | Not Implemented |
KU0493 # 01 Y:1998 | 01 | 1998 | USE OPTIMUM TEMPERATURE | $28,340 | $3,500 | Implemented |
KU0493 # 02 Y:1998 | 02 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,810 | $0 | Not Implemented |
KU0493 # 03 Y:1998 | 03 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,340 | $9,530 | Implemented |
KU0493 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,290 | $4,940 | Implemented |
KU0493 # 05 Y:1998 | 05 | 1998 | ISOLATE HOT OR COLD EQUIPMENT | $1,310 | $1,000 | Implemented |
KU0493 # 07 Y:1998 | 07 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $600 | $1,000 | Implemented |
KU0493 # 08 Y:1998 | 08 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $460 | $540 | Implemented |
KU0493 # 09 Y:1998 | 09 | 1998 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $60,681 | $3,050 | Not Implemented |
KU0493 # 10 Y:1998 | 10 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $77,980 | $2,020 | Not Implemented |
KU0493 # 11 Y:1998 | 11 | 1998 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $580 | $1,050 | Implemented |
KU0493 # 12 Y:1998 | 12 | 1998 | PURCHASE HIGH MATERIALS IN RETURNABLE BULK CONTAINERS | $530 | $90 | Not Implemented |
MO0198 # 09 Y:1997 | 09 | 1997 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $4,582 | $8,400 | Not Implemented |
MO0198 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $148 | $0 | Implemented |
MO0198 # 07 Y:1997 | 07 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $243 | $48 | Implemented |