Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
474
matching recommendationsSIC | 2092 | Fresh Or Frozen Prepared Fish |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0599 # 02 Y:2012 | 02 | 2012 | INSTALL AUTOMATIC PACKING EQUIPMENT | $35,308 | $0 | Implemented |
OR0599 # 03 Y:2012 | 03 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,422 | $0 | Not Implemented |
OR0599 # 04 Y:2012 | 04 | 2012 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,409 | $0 | Implemented |
OR0599 # 05 Y:2012 | 05 | 2012 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,964 | $17,576 | Not Implemented |
MA0669 # 07 Y:2011 | 07 | 2011 | INSULATE BARE EQUIPMENT | $410 | $550 | Implemented |
MA0669 # 06 Y:2011 | 06 | 2011 | INSULATE BARE EQUIPMENT | $736 | $349 | Not Implemented |
MA0669 # 05 Y:2011 | 05 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,576 | $25,250 | Not Implemented |
MA0669 # 04 Y:2011 | 04 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,848 | $1,500 | Implemented |
MA0669 # 03 Y:2011 | 03 | 2011 | OPTIMIZE PLANT POWER FACTOR | $10,179 | $11,190 | Implemented |
MA0669 # 02 Y:2011 | 02 | 2011 | INSULATE BARE EQUIPMENT | $12,439 | $25,000 | Not Implemented |
MA0669 # 01 Y:2011 | 01 | 2011 | REPLACE BOILER | $28,774 | $63,300 | Implemented |
UA0053 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,526 | $53,770 | Not Implemented |
UA0053 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,266 | $13,725 | Not Implemented |
UA0053 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $2,400 | $1,080 | Not Implemented |
UA0053 # 04 Y:2010 | 04 | 2010 | USE PHOTOCELL CONTROLS | $218 | $177 | Implemented |
UA0053 # 05 Y:2010 | 05 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $351 | $906 | Implemented |
UA0053 # 06 Y:2010 | 06 | 2010 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $4,505 | $1,000 | Implemented |
UA0053 # 07 Y:2010 | 07 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,870 | $26,550 | Not Implemented |
UA0053 # 08 Y:2010 | 08 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,306 | $7,045 | Not Implemented |
UA0053 # 09 Y:2010 | 09 | 2010 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $27,920 | $8,875 | Not Implemented |
LL0302 # 01 Y:2008 | 01 | 2008 | AIR CONDITION ONLY SPACE NECESSARY | $14,663 | $30 | Implemented |
LL0302 # 02 Y:2008 | 02 | 2008 | INSULATE BARE EQUIPMENT | $10,611 | $75,579 | Not Implemented |
LL0302 # 03 Y:2008 | 03 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,364 | $450 | Implemented |
LL0302 # 04 Y:2008 | 04 | 2008 | INSULATE BARE EQUIPMENT | $6,658 | $38,670 | Not Implemented |
LL0302 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $788 | $59 | Not Implemented |