Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
238
matching recommendationsSIC | 2096 | Potato Chips And Similar Snacks |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0215 # 08 Y:2001 | 08 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $97 | $780 | Implemented |
WV0215 # 09 Y:2001 | 09 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $3,456 | $100 | Implemented |
WV0215 # 10 Y:2001 | 10 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,440 | $100 | Implemented |
WV0200 # 01 Y:2000 | 01 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,112 | $25 | Implemented |
WV0200 # 03 Y:2000 | 03 | 2000 | USE SYNTHETIC LUBRICANT | $1,587 | $727 | Implemented |
WV0200 # 04 Y:2000 | 04 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $471 | $500 | Implemented |
WV0200 # 05 Y:2000 | 05 | 2000 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $2,070 | $1,012 | Implemented |
WV0200 # 06 Y:2000 | 06 | 2000 | INSULATE BARE EQUIPMENT | $3,609 | $636 | Implemented |
WV0200 # 09 Y:2000 | 09 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $34,531 | $0 | Implemented |
UD0592 # 02 Y:2000 | 02 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $8,655 | $8,000 | Implemented |
UD0592 # 04 Y:2000 | 04 | 2000 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $5,506 | $2,000 | Implemented |
TN0650 # 02 Y:1999 | 02 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,400 | $0 | Implemented |
TN0650 # 03 Y:1999 | 03 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $8,150 | $0 | Implemented |
OR0338 # 01 Y:1999 | 01 | 1999 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $14,000 | $1,630 | Implemented |
AM0304 # 01 Y:1997 | 01 | 1997 | REDUCE SCRAP PRODUCTION | $13,950 | $3,000 | Implemented |
AM0304 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $940 | $975 | Implemented |
AM0304 # 05 Y:1997 | 05 | 1997 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $750 | $0 | Implemented |
AM0304 # 07 Y:1997 | 07 | 1997 | REPAIR AND ELIMINATE STEAM LEAKS | $190 | $65 | Implemented |
AM0304 # 08 Y:1997 | 08 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $115 | $0 | Implemented |
AM0304 # 09 Y:1997 | 09 | 1997 | DISCONNECT BALLASTS | $110 | $10 | Implemented |
OR0291 # 02 Y:1997 | 02 | 1997 | BURN WOOD BY-PRODUCTS FOR HEAT | $5,024 | $0 | Implemented |
OR0291 # 03 Y:1997 | 03 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $814 | $0 | Implemented |
OR0291 # 08 Y:1997 | 08 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $883 | $2,029 | Implemented |
IA0162 # 01 Y:1996 | 01 | 1996 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,085 | $1,030 | Implemented |
IA0162 # 04 Y:1996 | 04 | 1996 | INSTALL OCCUPANCY SENSORS | $627 | $693 | Implemented |