Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,239
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0107 # 01 Y:2001 | 01 | 2001 | IMPROVE LUBRICATION PRACTICES | $272 | $200 | Implemented |
LE0107 # 02 Y:2001 | 02 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $639 | $0 | Implemented |
LE0107 # 03 Y:2001 | 03 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $304 | $0 | Implemented |
LE0107 # 04 Y:2001 | 04 | 2001 | INSTALL SET-BACK TIMERS | $7,324 | $2,100 | Not Implemented |
LE0107 # 05 Y:2001 | 05 | 2001 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $853 | $500 | Not Implemented |
LE0107 # 06 Y:2001 | 06 | 2001 | USE OPTIMUM THICKNESS INSULATION | $246 | $350 | Implemented |
LE0107 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,622 | $2,820 | Not Implemented |
GT0708 # 01 Y:2001 | 01 | 2001 | MOVE BOILER TO MORE EFFICIENT LOCATION | $7,140 | $0 | Implemented |
GT0708 # 02 Y:2001 | 02 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,765 | $0 | Implemented |
GT0708 # 03 Y:2001 | 03 | 2001 | COMBINE UTILITY METERS | $11,677 | $1,000 | Not Implemented |
GT0708 # 04 Y:2001 | 04 | 2001 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $38,843 | $13,500 | Implemented |
GT0708 # 05 Y:2001 | 05 | 2001 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $132,090 | $60,000 | Not Implemented |
GT0708 # 06 Y:2001 | 06 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $9,164 | $10,500 | Implemented |
GT0708 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,650 | $21,400 | Implemented |
NC0209 # 01 Y:2001 | 01 | 2001 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,845 | $5,600 | Not Implemented |
NC0209 # 02 Y:2001 | 02 | 2001 | UPGRADE CONTROLS ON COMPRESSORS | $2,519 | $5,600 | Implemented |
NC0209 # 03 Y:2001 | 03 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,161 | $5,700 | Not Implemented |
NC0209 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $163 | $200 | Implemented |
NC0209 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,886 | $2,360 | Implemented |
NC0209 # 06 Y:2001 | 06 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $675 | $200 | Not Implemented |
GT0705 # 01 Y:2000 | 01 | 2000 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $37,979 | $10,000 | Not Implemented |
GT0705 # 02 Y:2000 | 02 | 2000 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $6,635 | $8,000 | Not Implemented |
GT0705 # 03 Y:2000 | 03 | 2000 | MINIMIZE WATER USAGE | $1,457 | $300 | Implemented |
GT0705 # 04 Y:2000 | 04 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,420 | $0 | Implemented |
GT0705 # 05 Y:2000 | 05 | 2000 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $3,265 | $0 | Not Implemented |