Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,239

matching recommendations
Reset
SIC 22 Textile Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OD0085 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,532 $3,048 n/a
OD0085 # 02 Y:1997 02 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,568 $589 n/a
OD0085 # 03 Y:1997 03 1997 RECOVER WASTE HEAT FROM EQUIPMENT $1,915 $1,750 n/a
OD0085 # 04 Y:1997 04 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,962 $1,495 n/a
OD0085 # 05 Y:1997 05 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,327 $2,285 n/a
OD0085 # 06 Y:1997 06 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $6,000 $0 n/a
OD0085 # 07 Y:1997 07 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $5,368 $0 n/a
OD0085 # 08 Y:1997 08 1997 EXPAND OPERATIONS INTO UNUSED SPACE $100,000 $51,000 n/a
NC0112 # 01 Y:1997 01 1997 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $9,780 $0 n/a
NC0112 # 02 Y:1997 02 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,183 $397 n/a
NC0112 # 03 Y:1997 03 1997 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $1,601 $20 n/a
NC0112 # 04 Y:1997 04 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $10,698 $300 n/a
NC0112 # 05 Y:1997 05 1997 RECOVER AND REUSE WASTE MATERIAL $16,220 $260 n/a
NC0112 # 06 Y:1997 06 1997 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $7,750 $10,280 n/a
NC0112 # 07 Y:1997 07 1997 EXPAND OPERATIONS INTO UNUSED SPACE $60,000 $1,080 n/a
ME0218 # 01 Y:1997 01 1997 INSTALL AUTOMATIC PACKING EQUIPMENT $54,750 $10,120 Implemented
ME0218 # 02 Y:1997 02 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $9,110 $20,420 Not Implemented
ME0218 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,379 $15,318 Not Implemented
ME0218 # 04 Y:1997 04 1997 USE OPTIMUM THICKNESS INSULATION $2,188 $1,640 Not Implemented
ME0218 # 05 Y:1997 05 1997 RECOVER WASTE HEAT FROM EQUIPMENT $2,711 $3,950 Not Implemented
ME0218 # 06 Y:1997 06 1997 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $11,213 $1,400 Implemented
ME0218 # 07 Y:1997 07 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $3,300 $0 Not Implemented
ME0218 # 08 Y:1997 08 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $580 $1,840 Not Implemented
ME0218 # 09 Y:1997 09 1997 MINIMIZE WATER USAGE $412 $0 Not Implemented
AS0204 # 01 Y:1997 01 1997 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $63,320 $2,400 Not Implemented