Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,239

matching recommendations
Reset
SIC 22 Textile Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0824 # 05 Y:2006 05 2006 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $4,702 $600 Not Implemented
GT0824 # 06 Y:2006 06 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $16,185 $1,320 Not Implemented
GT0824 # 07 Y:2006 07 2006 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $8,644 $0 Implemented
GT0825 # 01 Y:2006 01 2006 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $14,828 $0 Not Implemented
GT0825 # 02 Y:2006 02 2006 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $95,828 $140,000 Not Implemented
GT0825 # 03 Y:2006 03 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,150 $4,150 Not Implemented
GT0825 # 04 Y:2006 04 2006 INSTALL OCCUPANCY SENSORS $13,107 $1,500 Not Implemented
GT0825 # 05 Y:2006 05 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $78,754 $182,180 Not Implemented
GT0817 # 01 Y:2006 01 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $8,981 $1,333 Implemented
GT0817 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $40,933 $164,201 Not Implemented
GT0817 # 03 Y:2006 03 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,177 $9,625 Not Implemented
GT0817 # 04 Y:2006 04 2006 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $3,469 $7,920 Not Implemented
GT0817 # 05 Y:2006 05 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,652 $500 Implemented
GT0817 # 06 Y:2006 06 2006 UPGRADE CONTROLS ON COMPRESSORS $2,666 $1,500 Implemented
GT0817 # 07 Y:2006 07 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $32,042 $15,000 Not Implemented
GT0817 # 08 Y:2006 08 2006 COMBINE UTILITY METERS $1,987 $0 Not Implemented
GT0818 # 01 Y:2006 01 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,499 $4,242 Implemented
GT0818 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $577 $356 Implemented
GT0818 # 03 Y:2006 03 2006 USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING $71,569 $250,000 Not Implemented
GT0818 # 04 Y:2006 04 2006 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $46,640 $7,200 Not Implemented
GT0818 # 05 Y:2006 05 2006 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $37,004 $3,300 Not Implemented
GT0818 # 06 Y:2006 06 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $21,314 $7,500 Not Implemented
GT0814 # 01 Y:2005 01 2005 RECOVER WASTE HEAT FROM EQUIPMENT $39,400 $50,000 Not Implemented
GT0814 # 02 Y:2005 02 2005 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $235,000 $20,000 Not Implemented
GT0814 # 03 Y:2005 03 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $85,200 $10,000 Not Implemented