Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
40
matching recommendationsSIC | 2211 | Broadwoven Fabric Mills, Cotton |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0493 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,789 | $215,791 | Implemented |
NC0493 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,550 | $1,386 | Implemented |
NC0493 # 05 Y:2013 | 05 | 2013 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $37,850 | $6,372 | Implemented |
NC0493 # 13 Y:2013 | 13 | 2013 | CONDENSE OPERATION INTO ONE BUILDING | $21,473 | $10,000 | Implemented |
NC0493 # 10 Y:2013 | 10 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,165 | $100 | Implemented |
NC0493 # 09 Y:2013 | 09 | 2013 | REDUCE EXCESSIVE BOILER BLOWDOWN | $430 | $0 | Implemented |
NC0284 # 01 Y:2004 | 01 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,310 | $26,200 | Implemented |
NC0284 # 02 Y:2004 | 02 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,667 | $10,600 | Implemented |
NC0284 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,521 | $1,002 | Implemented |
NC0284 # 07 Y:2004 | 07 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $469 | $1,000 | Implemented |
TN0369 # 10 Y:1989 | 10 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,943 | $450 | Implemented |
TN0369 # 03 Y:1989 | 03 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $1,909 | $240 | Implemented |
TN0369 # 04 Y:1989 | 04 | 1989 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $2,350 | $3,325 | Implemented |
TN0369 # 05 Y:1989 | 05 | 1989 | INSTALL SET-BACK TIMERS | $11,956 | $0 | Implemented |
TN0369 # 07 Y:1989 | 07 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $280 | $0 | Implemented |
TN0369 # 08 Y:1989 | 08 | 1989 | CLOSE OFF UNNEEDED STEAM LINES | $845 | $0 | Implemented |
TN0369 # 09 Y:1989 | 09 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $147 | $50 | Implemented |
AT0093 # 06 Y:1988 | 06 | 1988 | IMPROVE LUBRICATION PRACTICES | $1,829 | $0 | Implemented |
AT0093 # 08 Y:1988 | 08 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $336 | $150 | Implemented |
AT0093 # 07 Y:1988 | 07 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $884 | $0 | Implemented |
AT0093 # 05 Y:1988 | 05 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $419 | $746 | Implemented |
AT0093 # 03 Y:1988 | 03 | 1988 | INSULATE BARE EQUIPMENT | $281 | $200 | Implemented |
AT0093 # 02 Y:1988 | 02 | 1988 | INSTALL / REPAIR INSULATION ON STEAM LINES | $770 | $130 | Implemented |
AT0093 # 01 Y:1988 | 01 | 1988 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $124,949 | $261,000 | Implemented |
AT0092 # 02 Y:1988 | 02 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,033 | $2,092 | Implemented |