Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
264
matching recommendationsSIC | 2221 | Broadwoven Fabric Mills, Manmade |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0102 # 05 Y:1998 | 05 | 1998 | TURN OFF STEAM TRACING DURING MILD WEATHER | $5,726 | $0 | Implemented |
MS0102 # 06 Y:1998 | 06 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $7,306 | $47 | Implemented |
MS0102 # 07 Y:1998 | 07 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,227 | $8,447 | Not Implemented |
MS0102 # 08 Y:1998 | 08 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,767 | $22,372 | Not Implemented |
OD0092 # 01 Y:1997 | 01 | 1997 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $32,105 | $53,256 | Implemented |
OD0092 # 02 Y:1997 | 02 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $19,107 | $1,495 | Implemented |
OD0092 # 03 Y:1997 | 03 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,578 | $6,300 | Implemented |
OD0092 # 04 Y:1997 | 04 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $562 | $2,705 | Implemented |
OD0092 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,299 | $9,865 | Implemented |
OD0092 # 06 Y:1997 | 06 | 1997 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $10,500 | $4,095 | Implemented |
OD0092 # 07 Y:1997 | 07 | 1997 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $44,642 | $16,696 | Not Implemented |
ME0208 # 01 Y:1997 | 01 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,030 | $600 | Implemented |
ME0208 # 02 Y:1997 | 02 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,766 | $20 | Implemented |
ME0208 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,949 | $3,274 | Not Implemented |
ME0208 # 04 Y:1997 | 04 | 1997 | PAY UTILITY BILLS ON TIME | $1,220 | $0 | Implemented |
ME0208 # 05 Y:1997 | 05 | 1997 | USE OPTIMUM THICKNESS INSULATION | $788 | $290 | Implemented |
ME0208 # 06 Y:1997 | 06 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $738 | $200 | Not Implemented |
ME0208 # 07 Y:1997 | 07 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $452 | $0 | Implemented |
ME0208 # 08 Y:1997 | 08 | 1997 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $354 | $0 | Not Implemented |
ME0208 # 09 Y:1997 | 09 | 1997 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $24,276 | $6,900 | Implemented |
ME0208 # 10 Y:1997 | 10 | 1997 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $143 | $400 | Implemented |
TN0598 # 01 Y:1997 | 01 | 1997 | REDUCE SCRAP PRODUCTION | $151,000 | $13,920 | n/a |
TN0598 # 08 Y:1997 | 08 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,530 | $9,800 | n/a |
TN0598 # 06 Y:1997 | 06 | 1997 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $7,685 | $13,600 | n/a |
TN0598 # 07 Y:1997 | 07 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $5,900 | $0 | n/a |