Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
237
matching recommendationsSIC | 225 | Knitting Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0298 # 02 Y:2004 | 02 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $8,603 | $1,000 | Not Implemented |
NC0298 # 03 Y:2004 | 03 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,163 | $800 | Implemented |
NC0298 # 04 Y:2004 | 04 | 2004 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $1,175 | $1,200 | Implemented |
NC0298 # 05 Y:2004 | 05 | 2004 | CONVERT COMBUSTION EQUIPMENT TO BURN OIL | $21,805 | $15,800 | Not Implemented |
NC0298 # 06 Y:2004 | 06 | 2004 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,388 | $900 | Implemented |
NC0298 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $797 | $1,315 | Not Implemented |
NC0298 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $219 | $100 | Implemented |
NC0295 # 05 Y:2004 | 05 | 2004 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $288 | $500 | Not Implemented |
NC0295 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,454 | $3,840 | Not Implemented |
NC0295 # 03 Y:2004 | 03 | 2004 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $1,102 | $100 | Not Implemented |
NC0295 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,285 | $3,200 | Implemented |
NC0295 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,880 | $100 | Implemented |
NC0285 # 03 Y:2004 | 03 | 2004 | RECOVER AND REUSE COOLING WATER | $29,869 | $5,075 | Not Implemented |
NC0285 # 07 Y:2004 | 07 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,507 | $23,675 | Not Implemented |
NC0285 # 06 Y:2004 | 06 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $9,991 | $1,000 | Not Implemented |
NC0285 # 05 Y:2004 | 05 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $48,918 | $20,000 | Not Implemented |
NC0285 # 04 Y:2004 | 04 | 2004 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $956 | $1,380 | Not Implemented |
NC0285 # 02 Y:2004 | 02 | 2004 | RECOVER AND REUSE COOLING WATER | $7,258 | $8,763 | Not Implemented |
NC0285 # 08 Y:2004 | 08 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,454 | $500 | Not Implemented |
NC0285 # 01 Y:2004 | 01 | 2004 | RECOVER AND REUSE COOLING WATER | $84,488 | $67,500 | Not Implemented |
NC0242 # 01 Y:2002 | 01 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,271 | $1,000 | Implemented |
NC0242 # 02 Y:2002 | 02 | 2002 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $9,455 | $10,000 | Not Implemented |
NC0242 # 03 Y:2002 | 03 | 2002 | TREAT AND REUSE RINSE WATERS | $28,786 | $5,000 | Not Implemented |
NC0242 # 06 Y:2002 | 06 | 2002 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $2,368 | $1,200 | Implemented |
NC0242 # 07 Y:2002 | 07 | 2002 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $5,981 | $3,100 | Implemented |