Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
532
matching recommendationsSIC | 225 | Knitting Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0298 # 04 Y:2004 | 04 | 2004 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $1,175 | $1,200 | Implemented |
NC0298 # 05 Y:2004 | 05 | 2004 | CONVERT COMBUSTION EQUIPMENT TO BURN OIL | $21,805 | $15,800 | Not Implemented |
NC0298 # 06 Y:2004 | 06 | 2004 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,388 | $900 | Implemented |
NC0298 # 07 Y:2004 | 07 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,037 | $1,335 | Implemented |
NC0298 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $797 | $1,315 | Not Implemented |
NC0298 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $219 | $100 | Implemented |
NC0295 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,880 | $100 | Implemented |
NC0295 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,285 | $3,200 | Implemented |
NC0295 # 03 Y:2004 | 03 | 2004 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $1,102 | $100 | Not Implemented |
NC0295 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,454 | $3,840 | Not Implemented |
NC0295 # 05 Y:2004 | 05 | 2004 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $288 | $500 | Not Implemented |
NC0285 # 01 Y:2004 | 01 | 2004 | RECOVER AND REUSE COOLING WATER | $84,488 | $67,500 | Not Implemented |
NC0285 # 02 Y:2004 | 02 | 2004 | RECOVER AND REUSE COOLING WATER | $7,258 | $8,763 | Not Implemented |
NC0285 # 03 Y:2004 | 03 | 2004 | RECOVER AND REUSE COOLING WATER | $29,869 | $5,075 | Not Implemented |
NC0285 # 04 Y:2004 | 04 | 2004 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $956 | $1,380 | Not Implemented |
NC0285 # 05 Y:2004 | 05 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $48,918 | $20,000 | Not Implemented |
NC0285 # 06 Y:2004 | 06 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $9,991 | $1,000 | Not Implemented |
NC0285 # 07 Y:2004 | 07 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,507 | $23,675 | Not Implemented |
NC0285 # 08 Y:2004 | 08 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,454 | $500 | Not Implemented |
MA0534 # 01 Y:2003 | 01 | 2003 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $223,213 | $1,257,060 | Not Implemented |
MA0534 # 02 Y:2003 | 02 | 2003 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $76,320 | $57,480 | Not Implemented |
MA0534 # 03 Y:2003 | 03 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,487 | $53,950 | Not Implemented |
MA0534 # 04 Y:2003 | 04 | 2003 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $20,457 | $67,665 | Not Implemented |
MA0534 # 05 Y:2003 | 05 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $19,634 | $12,975 | Not Implemented |
MA0534 # 06 Y:2003 | 06 | 2003 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $10,591 | $8,425 | Not Implemented |