IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

206

matching recommendations
Reset
SIC 2252 Hosiery, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0298 # 09 Y:2004 09 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $219 $100 Implemented
NC0298 # 08 Y:2004 08 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $797 $1,315 Not Implemented
NC0298 # 07 Y:2004 07 2004 INSTALL / REPAIR INSULATION ON STEAM LINES $1,037 $1,335 Implemented
NC0298 # 06 Y:2004 06 2004 INCREASE AMOUNT OF CONDENSATE RETURNED $1,388 $900 Implemented
NC0298 # 05 Y:2004 05 2004 CONVERT COMBUSTION EQUIPMENT TO BURN OIL $21,805 $15,800 Not Implemented
NC0298 # 04 Y:2004 04 2004 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $1,175 $1,200 Implemented
NC0298 # 03 Y:2004 03 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $1,163 $800 Implemented
NC0298 # 02 Y:2004 02 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $8,603 $1,000 Not Implemented
NC0298 # 01 Y:2004 01 2004 INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT $9,750 $0 Implemented
NC0295 # 02 Y:2004 02 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,285 $3,200 Implemented
NC0295 # 01 Y:2004 01 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,880 $100 Implemented
NC0295 # 05 Y:2004 05 2004 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $288 $500 Not Implemented
NC0295 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,454 $3,840 Not Implemented
NC0295 # 03 Y:2004 03 2004 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $1,102 $100 Not Implemented
NC0242 # 01 Y:2002 01 2002 ADJUST BURNERS FOR EFFICIENT OPERATION $10,271 $1,000 Implemented
NC0242 # 07 Y:2002 07 2002 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $5,981 $3,100 Implemented
NC0242 # 06 Y:2002 06 2002 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $2,368 $1,200 Implemented
NC0242 # 05 Y:2002 05 2002 DEVELOP A REPAIR/REPLACE POLICY $547 $369 Implemented
NC0242 # 04 Y:2002 04 2002 INSULATE BARE EQUIPMENT $6,131 $10,062 Not Implemented
NC0242 # 03 Y:2002 03 2002 TREAT AND REUSE RINSE WATERS $28,786 $5,000 Not Implemented
NC0242 # 02 Y:2002 02 2002 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM $9,455 $10,000 Not Implemented
NC0217 # 05 Y:2001 05 2001 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $22,804 $35,000 Not Implemented
NC0217 # 02 Y:2001 02 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,659 $6,560 Implemented
NC0217 # 04 Y:2001 04 2001 INSULATE BARE EQUIPMENT $2,283 $1,180 Not Implemented
NC0217 # 03 Y:2001 03 2001 RECOVER WASTE HEAT FROM EQUIPMENT $6,328 $5,000 Not Implemented