Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
121
matching recommendationsSIC | 226 | Textile Finishing, Except Wool |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0246 # 06 Y:1985 | 06 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $449 | $800 | Implemented |
GT0246 # 07 Y:1985 | 07 | 1985 | BURN A LESS EXPENSIVE GRADE OF FUEL | $63,458 | $120,000 | Not Implemented |
GT0217 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $20,387 | $200 | Implemented |
GT0217 # 02 Y:1984 | 02 | 1984 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $11,700 | $10,000 | Implemented |
GT0217 # 03 Y:1984 | 03 | 1984 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $188,200 | $270,000 | Not Implemented |
GT0217 # 04 Y:1984 | 04 | 1984 | MODIFY TEXTILE DRYERS | $51,600 | $23,000 | Not Implemented |
GT0217 # 05 Y:1984 | 05 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $19,960 | $1,000 | Implemented |
GT0217 # 06 Y:1984 | 06 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,670 | $640 | Implemented |
GT0217 # 07 Y:1984 | 07 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,040 | $400 | Not Implemented |
GT0217 # 08 Y:1984 | 08 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,890 | $2,520 | Not Implemented |
GT0211 # 01 Y:1984 | 01 | 1984 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $19,964 | $32,000 | Implemented |
GT0211 # 02 Y:1984 | 02 | 1984 | COVER OPEN TANKS | $2,894 | $4,000 | Implemented |
GT0211 # 03 Y:1984 | 03 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $300 | $50 | Implemented |
GT0211 # 04 Y:1984 | 04 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $985 | $432 | Implemented |
GT0211 # 05 Y:1984 | 05 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $335 | $148 | Implemented |
GT0211 # 06 Y:1984 | 06 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $808 | $104 | Implemented |
GT0211 # 07 Y:1984 | 07 | 1984 | BURN A LESS EXPENSIVE GRADE OF FUEL | $67,362 | $200,000 | Implemented |
GT0211 # 08 Y:1984 | 08 | 1984 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,000 | $8,000 | Implemented |
GT0206 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,815 | $200 | Implemented |
GT0206 # 02 Y:1984 | 02 | 1984 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $8,580 | $4,500 | Implemented |
GT0206 # 03 Y:1984 | 03 | 1984 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $14,224 | $9,000 | Implemented |
GT0206 # 04 Y:1984 | 04 | 1984 | INSULATE BARE EQUIPMENT | $5,168 | $6,540 | Not Implemented |
GT0204 # 01 Y:1983 | 01 | 1983 | MODIFY TEXTILE DRYERS | $74,410 | $50,000 | Not Implemented |
GT0204 # 02 Y:1983 | 02 | 1983 | MODIFY TEXTILE DRYERS | $67,354 | $50,000 | Not Implemented |
GT0204 # 03 Y:1983 | 03 | 1983 | REPAIR AND ELIMINATE STEAM LEAKS | $8,427 | $700 | Not Implemented |