Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

178

matching recommendations
Reset
SIC 2261 Finishing Plants, Cotton
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0388 # 08 Y:1997 08 1997 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $32,204 $55,094 Implemented
GT0594 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,591 $9,855 Implemented
GT0594 # 02 Y:1996 02 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,700 $1,263 Not Implemented
GT0594 # 03 Y:1996 03 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $13,380 $0 Implemented
GT0594 # 04 Y:1996 04 1996 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $5,740 $15,240 Not Implemented
GT0594 # 05 Y:1996 05 1996 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $112,836 $405,000 Implemented
TN0476 # 01 Y:1992 01 1992 INSULATE BARE EQUIPMENT $9,523 $2,425 Not Implemented
TN0476 # 02 Y:1992 02 1992 REPAIR AND ELIMINATE STEAM LEAKS $8,013 $2,350 Not Implemented
TN0476 # 03 Y:1992 03 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $56,030 $36,440 Not Implemented
TN0476 # 04 Y:1992 04 1992 INSTALL / REPAIR INSULATION ON STEAM LINES $4,854 $1,100 Not Implemented
TN0476 # 05 Y:1992 05 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,303 $2,307 Not Implemented
TN0476 # 06 Y:1992 06 1992 IMPROVE LUBRICATION PRACTICES $3,357 $0 Not Implemented
GT0422 # 01 Y:1990 01 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,202 $172 Implemented
GT0422 # 02 Y:1990 02 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,600 $1,000 Implemented
GT0422 # 03 Y:1990 03 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $1,936 $1,790 Implemented
GT0422 # 04 Y:1990 04 1990 IMPROVE LUBRICATION PRACTICES $350 $0 Implemented
AM0067 # 01 Y:1989 01 1989 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $28,911 $6,400 Not Implemented
AM0067 # 02 Y:1989 02 1989 REPAIR AND ELIMINATE STEAM LEAKS $4,380 $800 Implemented
AM0067 # 03 Y:1989 03 1989 INSTALL SET-BACK TIMERS $3,860 $0 Implemented
AM0067 # 04 Y:1989 04 1989 ELIMINATE LEAKS IN WATER LINES AND VALVES $2,932 $175 Implemented
AM0067 # 06 Y:1989 06 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $900 $800 Not Implemented
AM0067 # 07 Y:1989 07 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $154 $91 Not Implemented
AM0067 # 08 Y:1989 08 1989 INSTALL TIMERS AND/OR THERMOSTATS $285 $83 Not Implemented
AM0067 # 09 Y:1989 09 1989 CHECK FOR ACCURACY OF UTILITY / POWER METERS $94 $500 Not Implemented
GT0338 # 01 Y:1988 01 1988 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $30,000 $6,670 Implemented