Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
136
matching recommendationsSIC | 2261 | Finishing Plants, Cotton |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0653 # 02 Y:2009 | 02 | 2009 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $37,210 | $68,000 | Not Implemented |
MA0653 # 06 Y:2009 | 06 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,375 | $6,125 | Not Implemented |
MA0653 # 03 Y:2009 | 03 | 2009 | REDUCE VENTILATION AIR | $16,188 | $752 | Implemented |
MA0653 # 01 Y:2009 | 01 | 2009 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $110,550 | $270,000 | Not Implemented |
MA0653 # 05 Y:2009 | 05 | 2009 | INSULATE BARE EQUIPMENT | $2,840 | $7,510 | Implemented |
MA0653 # 04 Y:2009 | 04 | 2009 | CLOSE OFF UNNEEDED STEAM LINES | $3,551 | $500 | Not Implemented |
LM0121 # 04 Y:2006 | 04 | 2006 | INSULATE BARE EQUIPMENT | $3,734 | $3,100 | Implemented |
LM0121 # 02 Y:2006 | 02 | 2006 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $91,500 | $200 | Not Implemented |
LM0121 # 01 Y:2006 | 01 | 2006 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $183,000 | $2,160 | Not Implemented |
LM0121 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,390 | $10,233 | Implemented |
GT0754 # 02 Y:2003 | 02 | 2003 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $146,600 | $104,000 | Implemented |
GT0754 # 10 Y:2003 | 10 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $26,325 | $5,750 | Not Implemented |
GT0754 # 01 Y:2003 | 01 | 2003 | BURN A LESS EXPENSIVE GRADE OF FUEL | $24,451 | $69,000 | Implemented |
GT0754 # 03 Y:2003 | 03 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,080 | $0 | Implemented |
GT0754 # 05 Y:2003 | 05 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $840 | $678 | Implemented |
GT0754 # 09 Y:2003 | 09 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,607 | $1,414 | Implemented |
GT0754 # 06 Y:2003 | 06 | 2003 | INCREASE AMOUNT OF CONDENSATE RETURNED | $87,548 | $12,750 | Implemented |
GT0754 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,324 | $2,271 | Implemented |
GT0754 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $788 | $1,731 | Not Implemented |
GT0754 # 07 Y:2003 | 07 | 2003 | COVER OPEN TANKS | $16,490 | $6,500 | Not Implemented |
GT0754 # 11 Y:2003 | 11 | 2003 | RECOVER AND REUSE COOLING WATER | $293,681 | $201,600 | Implemented |
MA0516 # 08 Y:2002 | 08 | 2002 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $560 | $0 | Not Implemented |
MA0516 # 02 Y:2002 | 02 | 2002 | MINIMIZE WATER USAGE | $43,582 | $43,100 | Not Implemented |
MA0516 # 09 Y:2002 | 09 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,704 | $15,768 | Not Implemented |
MA0516 # 03 Y:2002 | 03 | 2002 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $14,155 | $19,000 | Not Implemented |