Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
96
matching recommendationsSIC | 2329 | Men's and Boys' Clothing, Not Elsewhere Classified |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0027 # 08 Y:1992 | 08 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $260 | $20 | Implemented |
OK0372 # 02 Y:1992 | 02 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $3,782 | $2,888 | Implemented |
OK0372 # 03 Y:1992 | 03 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $4,890 | $16,670 | Implemented |
TN0420 # 01 Y:1991 | 01 | 1991 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $25,653 | $0 | Implemented |
TN0420 # 08 Y:1991 | 08 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $460 | $832 | Implemented |
TN0420 # 02 Y:1991 | 02 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $21,120 | $0 | Implemented |
TN0420 # 03 Y:1991 | 03 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $13,672 | $5,600 | Implemented |
TN0420 # 04 Y:1991 | 04 | 1991 | USE COMPRESSOR AIR FILTERS | $2,380 | $50 | Implemented |
TN0420 # 05 Y:1991 | 05 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $330 | $980 | Implemented |
TN0420 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,064 | $3,176 | Implemented |
TN0420 # 09 Y:1991 | 09 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $328 | $0 | Implemented |
TN0420 # 07 Y:1991 | 07 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $492 | $150 | Implemented |
TN0420 # 10 Y:1991 | 10 | 1991 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $82 | $50 | Implemented |
TN0404 # 02 Y:1990 | 02 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,555 | $390 | Implemented |
TN0404 # 10 Y:1990 | 10 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $347 | $264 | Implemented |
TN0404 # 08 Y:1990 | 08 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $195 | $0 | Implemented |
TN0404 # 07 Y:1990 | 07 | 1990 | USE COMPRESSOR AIR FILTERS | $716 | $50 | Implemented |
TN0404 # 06 Y:1990 | 06 | 1990 | INSTALL SET-BACK TIMERS | $1,258 | $0 | Implemented |
TN0404 # 04 Y:1990 | 04 | 1990 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $760 | $0 | Implemented |
KU0274 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,538 | $7,607 | Implemented |
KU0274 # 02 Y:1989 | 02 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $3,173 | $0 | Implemented |
KU0274 # 03 Y:1989 | 03 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $362 | $300 | Implemented |
KU0274 # 04 Y:1989 | 04 | 1989 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $162 | $80 | Implemented |
KU0274 # 06 Y:1989 | 06 | 1989 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $251 | $0 | Implemented |
OK0241 # 06 Y:1987 | 06 | 1987 | INSTALL TURBULATORS | $108 | $220 | Implemented |