Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsSIC | 2396 | Automotive And Apparel Trimmings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
HO0187 # 06 Y:1998 | 06 | 1998 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $1,125 | $100 | Implemented |
HO0187 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,545 | $90,112 | Not Implemented |
HO0187 # 02 Y:1998 | 02 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $133 | $415 | Not Implemented |
HO0187 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $267 | $500 | Implemented |
HO0187 # 04 Y:1998 | 04 | 1998 | INSULATE BARE EQUIPMENT | $1,092 | $650 | Not Implemented |
HO0187 # 05 Y:1998 | 05 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $807 | $250 | Implemented |
TN0632 # 07 Y:1998 | 07 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $32,400 | $47,100 | Implemented |
TN0632 # 06 Y:1998 | 06 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $1,520 | $1,260 | Implemented |
TN0632 # 05 Y:1998 | 05 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,480 | $1,680 | Not Implemented |
TN0632 # 04 Y:1998 | 04 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,890 | $3,260 | Not Implemented |
TN0632 # 03 Y:1998 | 03 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $7,020 | $0 | Not Implemented |
TN0632 # 02 Y:1998 | 02 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,750 | $14,700 | Not Implemented |
TN0632 # 01 Y:1998 | 01 | 1998 | METER WASTE WATER | $18,830 | $3,300 | Implemented |
HO0176 # 02 Y:1998 | 02 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $640 | $625 | Implemented |
HO0176 # 09 Y:1998 | 09 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $833 | $500 | Implemented |
HO0176 # 08 Y:1998 | 08 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $12,800 | $500 | Implemented |
HO0176 # 07 Y:1998 | 07 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $4,000 | $500 | Implemented |
HO0176 # 06 Y:1998 | 06 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $9,729 | $500 | Implemented |
HO0176 # 05 Y:1998 | 05 | 1998 | CHANGE OPERATING CONDITIONS | $27,147 | $3,525 | Implemented |
HO0176 # 04 Y:1998 | 04 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,785 | $6,000 | Not Implemented |
HO0176 # 03 Y:1998 | 03 | 1998 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,026 | $1,000 | Not Implemented |
HO0176 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $913 | $1,443 | Implemented |
UM0104 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $249 | $540 | Implemented |
UM0104 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,708 | $8,483 | Implemented |
UM0104 # 03 Y:1998 | 03 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,449 | $0 | Implemented |