Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,167
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0333 # 02 Y:1998 | 02 | 1998 | USE OPTIMUM TEMPERATURE | $5,560 | $1,800 | Not Implemented |
OR0333 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,495 | $4,550 | Not Implemented |
OR0333 # 04 Y:1998 | 04 | 1998 | UPGRADE CONTROLS ON COMPRESSORS | $6,395 | $9,600 | Not Implemented |
OR0332 # 01 Y:1998 | 01 | 1998 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $77,144 | $350,000 | Not Implemented |
OR0332 # 02 Y:1998 | 02 | 1998 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $5,644 | $0 | Implemented |
OR0332 # 03 Y:1998 | 03 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $53,320 | $75,400 | Not Implemented |
OR0332 # 04 Y:1998 | 04 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $19,647 | $87,375 | Not Implemented |
OR0332 # 05 Y:1998 | 05 | 1998 | OPTIMIZE PLANT POWER FACTOR | $0 | $54,400 | Implemented |
OR0332 # 06 Y:1998 | 06 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,450 | $0 | Implemented |
OR0332 # 07 Y:1998 | 07 | 1998 | UPGRADE CONTROLS ON COMPRESSORS | $2,696 | $1,200 | Not Implemented |
OR0332 # 08 Y:1998 | 08 | 1998 | INSTALL REDUNDANT EQUIPMENT TO AVOID LOSSES CAUSED BY EQUIPMENT FAILURE AND ROUTINE MAINTENANCE | $16,275 | $7,000 | Not Implemented |
OR0332 # 09 Y:1998 | 09 | 1998 | INSTALL BACK-UP EQUIPMENT | $103,215 | $408,000 | Not Implemented |
OR0332 # 10 Y:1998 | 10 | 1998 | USE OTHER WASTE CONCENTRATION METHODS | $68,930 | $131,400 | Implemented |
OR0325 # 01 Y:1998 | 01 | 1998 | ADJUST BURNERS FOR EFFICIENT OPERATION | $5,486 | $500 | Not Implemented |
OR0325 # 02 Y:1998 | 02 | 1998 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $16,215 | $6,816 | Not Implemented |
OR0325 # 03 Y:1998 | 03 | 1998 | ADJUST BURNERS FOR EFFICIENT OPERATION | $4,674 | $0 | Implemented |
OR0325 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,213 | $1,000 | Not Implemented |
OR0325 # 05 Y:1998 | 05 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $970 | $0 | Not Implemented |
OR0287 # 01 Y:1997 | 01 | 1997 | REVISE RAW MATERIAL SPECS | $32,300 | $104,000 | Not Implemented |
OR0287 # 02 Y:1997 | 02 | 1997 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $17,270 | $0 | Not Implemented |
OR0287 # 03 Y:1997 | 03 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $480 | $0 | Implemented |
OR0287 # 04 Y:1997 | 04 | 1997 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $260 | $0 | Not Implemented |
OR0287 # 05 Y:1997 | 05 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,770 | $2,885 | Implemented |
OR0287 # 06 Y:1997 | 06 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $0 | $2,000 | Implemented |
OR0287 # 07 Y:1997 | 07 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $450 | $2,000 | Not Implemented |