Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
215
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0496 # 09 Y:2006 | 09 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,425 | $0 | Not Implemented |
OR0496 # 10 Y:2006 | 10 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $780 | $295 | Not Implemented |
OR0496 # 11 Y:2006 | 11 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $415 | $600 | Not Implemented |
OR0495 # 01 Y:2006 | 01 | 2006 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $249,000 | $15,000 | Not Implemented |
OR0495 # 02 Y:2006 | 02 | 2006 | $379,000 | $168,000 | Not Implemented | |
OR0495 # 03 Y:2006 | 03 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $15,400 | $6,000 | Not Implemented |
OR0495 # 04 Y:2006 | 04 | 2006 | OPTIMIZE PLANT POWER FACTOR | $15,000 | $8,750 | Implemented |
OR0495 # 05 Y:2006 | 05 | 2006 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $8,900 | $900 | Implemented |
OR0495 # 06 Y:2006 | 06 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,800 | $1,500 | Not Implemented |
OR0495 # 07 Y:2006 | 07 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $3,900 | $1,800 | Implemented |
OR0495 # 08 Y:2006 | 08 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,400 | $2,100 | Not Implemented |
OR0495 # 09 Y:2006 | 09 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $13,300 | $13,100 | Implemented |
OR0495 # 10 Y:2006 | 10 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,700 | $4,700 | Implemented |
OR0495 # 11 Y:2006 | 11 | 2006 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $32,700 | $52,000 | Not Implemented |
OR0495 # 12 Y:2006 | 12 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $611,000 | $1,406,000 | Not Implemented |
OR0495 # 13 Y:2006 | 13 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $21,000 | $49,000 | Implemented |
OR0495 # 14 Y:2006 | 14 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,900 | $31,000 | Not Implemented |
OR0495 # 15 Y:2006 | 15 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,500 | $15,000 | Not Implemented |
OR0476 # 01 Y:2005 | 01 | 2005 | INSTALL SENSORS TO DETECT DEFECTS | $59,097 | $38,400 | Not Implemented |
OR0476 # 02 Y:2005 | 02 | 2005 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,039,000 | $1,200,000 | Not Implemented |
OR0476 # 03 Y:2005 | 03 | 2005 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $9,028 | $600 | Implemented |
OR0476 # 04 Y:2005 | 04 | 2005 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $32,100 | $47,900 | Not Implemented |
OR0449 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,830 | $8,000 | Implemented |
OR0449 # 02 Y:2004 | 02 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,100 | $2,600 | Implemented |
OR0449 # 03 Y:2004 | 03 | 2004 | MOVE PRODUCT USING MECHANICAL MEANS | $88,440 | $400 | Not Implemented |