Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
173
matching recommendationsSIC | 242 | Sawmills And Planing Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0367 # 03 Y:2008 | 03 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $11,577 | $1,336 | Implemented |
WV0367 # 04 Y:2008 | 04 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,511 | $0 | Implemented |
WV0367 # 05 Y:2008 | 05 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,892 | $485 | Not Implemented |
WV0367 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,538 | $0 | Implemented |
WV0367 # 07 Y:2008 | 07 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,042 | $185 | Not Implemented |
WV0367 # 08 Y:2008 | 08 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $780 | $2,158 | Implemented |
WV0333 # 01 Y:2006 | 01 | 2006 | BURN WASTE OIL FOR HEAT | $23,934 | $19,500 | Not Implemented |
WV0333 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,663 | $195 | Implemented |
WV0333 # 03 Y:2006 | 03 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $2,692 | $544 | Implemented |
WV0333 # 04 Y:2006 | 04 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,819 | $800 | Implemented |
WV0333 # 05 Y:2006 | 05 | 2006 | INSTALL OCCUPANCY SENSORS | $397 | $210 | Not Implemented |
WV0333 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $460 | $0 | Not Implemented |
WV0281 # 01 Y:2003 | 01 | 2003 | BURN A LESS EXPENSIVE GRADE OF FUEL | $52,226 | $153,000 | Not Implemented |
WV0281 # 02 Y:2003 | 02 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,150 | $1,695 | Not Implemented |
WV0281 # 03 Y:2003 | 03 | 2003 | DEVELOP A REPAIR/REPLACE POLICY | $1,940 | $240 | Implemented |
WV0281 # 04 Y:2003 | 04 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,652 | $1,000 | Implemented |
WV0281 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $1,163 | $38 | Implemented |
WV0274 # 01 Y:2003 | 01 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $22,034 | $1,640 | Not Implemented |
WV0274 # 02 Y:2003 | 02 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,198 | $1,000 | Implemented |
WV0274 # 03 Y:2003 | 03 | 2003 | MAINTAIN MACHINES TO REDUCE LEAKS | $5,774 | $35 | Implemented |
WV0274 # 04 Y:2003 | 04 | 2003 | INSULATE BARE EQUIPMENT | $3,173 | $252 | Implemented |
WV0274 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,432 | $2,093 | Not Implemented |
WV0274 # 06 Y:2003 | 06 | 2003 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,068 | $435 | Implemented |
WV0274 # 07 Y:2003 | 07 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $772 | $2,925 | Implemented |
WV0274 # 08 Y:2003 | 08 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $654 | $73 | Implemented |