Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,907
matching recommendationsSIC | 2421 | Sawmills And Planing Mills, General |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0035 # 09 Y:2009 | 09 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $3,810 | $2,210 | Implemented |
UA0035 # 10 Y:2009 | 10 | 2009 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $40,375 | $77,000 | Implemented |
UA0035 # 11 Y:2009 | 11 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $26,217 | $10,000 | Not Implemented |
AM0538 # 01 Y:2008 | 01 | 2008 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $192,300 | $174,034 | Not Implemented |
AM0538 # 02 Y:2008 | 02 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $171,000 | $5,000 | Implemented |
AM0538 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $41,905 | $105,000 | Implemented |
AM0538 # 04 Y:2008 | 04 | 2008 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $2,200,000 | $6,600,000 | Implemented |
AM0538 # 05 Y:2008 | 05 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,200 | $0 | Not Implemented |
AM0538 # 06 Y:2008 | 06 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,770 | $1,120 | Implemented |
AM0538 # 07 Y:2008 | 07 | 2008 | USE SYNTHETIC LUBRICANT | $1,045 | $0 | Not Implemented |
WV0367 # 01 Y:2008 | 01 | 2008 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $870,056 | $3,850,000 | Not Implemented |
WV0367 # 02 Y:2008 | 02 | 2008 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $16,386 | $3,500 | Implemented |
WV0367 # 03 Y:2008 | 03 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $11,577 | $1,336 | Implemented |
WV0367 # 08 Y:2008 | 08 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $780 | $2,158 | Implemented |
WV0367 # 07 Y:2008 | 07 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,042 | $185 | Not Implemented |
WV0367 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,538 | $0 | Implemented |
WV0367 # 05 Y:2008 | 05 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,892 | $485 | Not Implemented |
WV0367 # 04 Y:2008 | 04 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,511 | $0 | Implemented |
UA0012 # 01 Y:2007 | 01 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,155 | $700 | Implemented |
UA0012 # 02 Y:2007 | 02 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,165 | $0 | Implemented |
UA0012 # 03 Y:2007 | 03 | 2007 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $1,063,171 | $5,532,000 | Not Implemented |
UA0012 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,620 | $9,817 | Not Implemented |
UA0012 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $737 | $7,504 | Not Implemented |
UA0012 # 06 Y:2007 | 06 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,429 | $1,230 | Not Implemented |
OR0525 # 01 Y:2007 | 01 | 2007 | $246,000 | $900,000 | Not Implemented |