Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
494
matching recommendationsSIC | 243 | Millwork, Plywood & Structural |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0379 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,383 | $7,000 | Implemented |
OR0379 # 02 Y:2000 | 02 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $9,673 | $15,010 | Not Implemented |
OR0379 # 03 Y:2000 | 03 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,146 | $0 | Not Implemented |
OR0379 # 04 Y:2000 | 04 | 2000 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,099 | $885 | Implemented |
OR0379 # 05 Y:2000 | 05 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,229 | $0 | Not Implemented |
OR0379 # 06 Y:2000 | 06 | 2000 | COMBINE UTILITY METERS | $1,715 | $4,000 | Not Implemented |
OR0379 # 07 Y:2000 | 07 | 2000 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $9,628 | $48,484 | Implemented |
OR0379 # 08 Y:2000 | 08 | 2000 | OPTIMIZE PLANT POWER FACTOR | $7,013 | $19,600 | Not Implemented |
OR0379 # 09 Y:2000 | 09 | 2000 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $1,026,000 | $1,337,500 | Not Implemented |
OR0334 # 01 Y:1998 | 01 | 1998 | CONDENSE OPERATION INTO ONE BUILDING | $1,080,150 | $1,000,000 | Implemented |
OR0334 # 02 Y:1998 | 02 | 1998 | INSTALL EQUIPMENT TO MOVE PRODUCT | $14,550 | $31,520 | Implemented |
OR0334 # 03 Y:1998 | 03 | 1998 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $48,900 | $220,000 | Not Implemented |
OR0334 # 04 Y:1998 | 04 | 1998 | OPTIMIZE PLANT POWER FACTOR | $15,977 | $44,400 | Not Implemented |
OR0334 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,499 | $6,000 | Implemented |
OR0334 # 06 Y:1998 | 06 | 1998 | UPGRADE CONTROLS ON COMPRESSORS | $14,409 | $9,600 | Implemented |
OR0334 # 07 Y:1998 | 07 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,890 | $0 | Implemented |
OR0334 # 08 Y:1998 | 08 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $5,250 | $0 | Implemented |
OR0334 # 09 Y:1998 | 09 | 1998 | REGENERATE CLEANING SOLVENT ON-SITE AND REUSE | $1,146 | $350 | Not Implemented |
OR0325 # 01 Y:1998 | 01 | 1998 | ADJUST BURNERS FOR EFFICIENT OPERATION | $5,486 | $500 | Not Implemented |
OR0325 # 02 Y:1998 | 02 | 1998 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $16,215 | $6,816 | Not Implemented |
OR0325 # 03 Y:1998 | 03 | 1998 | ADJUST BURNERS FOR EFFICIENT OPERATION | $4,674 | $0 | Implemented |
OR0325 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,213 | $1,000 | Not Implemented |
OR0325 # 05 Y:1998 | 05 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $970 | $0 | Not Implemented |
OR0253 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $29,097 | $26,200 | Not Implemented |
OR0253 # 02 Y:1995 | 02 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,790 | $5,000 | Not Implemented |