Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
63
matching recommendationsSIC | 243 | Millwork, Plywood & Structural |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UW2312 # 02 Y:2023 | 02 | 2023 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,868 | $20 | n/a |
UW2312 # 03 Y:2023 | 03 | 2023 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,841 | $1,520 | n/a |
UW2312 # 05 Y:2023 | 05 | 2023 | OPTIMIZE PLANT POWER FACTOR | $10,128 | $13,235 | n/a |
UW2312 # 04 Y:2023 | 04 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $236,659 | $2,614,888 | n/a |
UW2312 # 01 Y:2023 | 01 | 2023 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,943 | $30,989 | n/a |
OR0701 # 02 Y:2018 | 02 | 2018 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $17,929 | $8,549 | Not Implemented |
OR0701 # 01 Y:2018 | 01 | 2018 | INSTALL SYSTEM TO COLLECT SCRAP | $35,903 | $29,900 | Not Implemented |
OR0701 # 03 Y:2018 | 03 | 2018 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $11,954 | $11,773 | Not Implemented |
OR0701 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,441 | $4,175 | Not Implemented |
OR0686 # 02 Y:2017 | 02 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,219 | $0 | Not Implemented |
OR0686 # 06 Y:2017 | 06 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,743 | $500 | Not Implemented |
OR0686 # 05 Y:2017 | 05 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,115 | $16,115 | Not Implemented |
OR0686 # 04 Y:2017 | 04 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,155 | $0 | Not Implemented |
OR0686 # 03 Y:2017 | 03 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $15,997 | $1,200 | Not Implemented |
OR0686 # 01 Y:2017 | 01 | 2017 | DEVELOP STANDARD OPERATING PROCEDURES | $181,947 | $31,400 | Not Implemented |
UW0005 # 09 Y:2007 | 09 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $354 | $650 | Not Implemented |
UW0005 # 01 Y:2007 | 01 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,804 | $7,172 | Implemented |
UW0005 # 02 Y:2007 | 02 | 2007 | REPOSITION OVEN WALLS TO REDUCE HEATED SPACE | $15,876 | $4,452 | Implemented |
UW0005 # 03 Y:2007 | 03 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $3,246 | $1,162 | Implemented |
UW0005 # 04 Y:2007 | 04 | 2007 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $8,530 | $1,852 | Not Implemented |
UW0005 # 05 Y:2007 | 05 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,388 | $2,619 | Implemented |
UW0005 # 06 Y:2007 | 06 | 2007 | OPTIMIZE PLANT POWER FACTOR | $6,971 | $17,098 | Not Implemented |
UW0005 # 07 Y:2007 | 07 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,766 | $432 | Implemented |
UW0005 # 08 Y:2007 | 08 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,795 | $398 | Implemented |
OR0496 # 11 Y:2006 | 11 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $415 | $600 | Not Implemented |