Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
51
matching recommendationsSIC | 2451 | Mobile Homes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0266 # 09 Y:2001 | 09 | 2001 | INSTALL SYSTEM TO COLLECT SCRAP | $14,581 | $4,926 | Not Implemented |
UF0266 # 08 Y:2001 | 08 | 2001 | RECOVER AND REUSE WASTE MATERIAL | $5,400 | $0 | Implemented |
UF0266 # 07 Y:2001 | 07 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $800 | $0 | Implemented |
UF0266 # 06 Y:2001 | 06 | 2001 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $5,591 | $0 | Not Implemented |
UF0266 # 05 Y:2001 | 05 | 2001 | INSTALL SKYLIGHTS | $21,467 | $60,291 | Not Implemented |
UF0266 # 04 Y:2001 | 04 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,037 | $0 | Implemented |
UF0266 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,081 | $410 | Implemented |
UF0266 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,082 | $5,941 | Not Implemented |
UF0266 # 01 Y:2001 | 01 | 2001 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,100 | $50 | Implemented |
UF0212 # 04 Y:1998 | 04 | 1998 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $1,314 | $1,818 | Implemented |
UF0212 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,912 | $4,901 | Implemented |
UF0212 # 02 Y:1998 | 02 | 1998 | ADD AREA LIGHTING SWITCHES | $2,592 | $1,614 | Not Implemented |
UF0212 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,198 | $1,438 | Implemented |
UF0212 # 05 Y:1998 | 05 | 1998 | REDUCE SCRAP PRODUCTION | $74,273 | $165,000 | Implemented |
UF0212 # 06 Y:1998 | 06 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $241,992 | $1,794 | Not Implemented |
UF0212 # 07 Y:1998 | 07 | 1998 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $176,631 | $34,209 | Not Implemented |
UF0175 # 08 Y:1997 | 08 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,434 | $0 | Not Implemented |
UF0175 # 07 Y:1997 | 07 | 1997 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $7,964 | $0 | Not Implemented |
UF0175 # 06 Y:1997 | 06 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $29,205 | $0 | Implemented |
UF0175 # 05 Y:1997 | 05 | 1997 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $622 | $850 | Implemented |
UF0175 # 04 Y:1997 | 04 | 1997 | REDUCE SCRAP PRODUCTION | $167,231 | $165,000 | Not Implemented |
UF0175 # 03 Y:1997 | 03 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,663 | $0 | Implemented |
UF0175 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,088 | $1,850 | Implemented |
UF0175 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $346 | $3,549 | Not Implemented |
UF0170 # 11 Y:1997 | 11 | 1997 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $18,237 | $3,120 | Implemented |