Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
26
matching recommendationsSIC | 2542 | Partitions And Fixtures, Except Wood |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0546 # 06 Y:2017 | 06 | 2017 | INSTALL OCCUPANCY SENSORS | $419 | $1,000 | Implemented |
SD0546 # 05 Y:2017 | 05 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $989 | $400 | Implemented |
SD0546 # 04 Y:2017 | 04 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,299 | $2,500 | Implemented |
SD0546 # 03 Y:2017 | 03 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,431 | $6,068 | Implemented |
SD0546 # 02 Y:2017 | 02 | 2017 | USE PHOTOCELL CONTROLS | $8,753 | $17,253 | Implemented |
SD0546 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,392 | $25,659 | Implemented |
SD0542 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,743 | $11,288 | Implemented |
SD0542 # 09 Y:2017 | 09 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $967 | $850 | Not Implemented |
SD0542 # 08 Y:2017 | 08 | 2017 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,153 | $2,288 | Implemented |
SD0542 # 07 Y:2017 | 07 | 2017 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $1,935 | $1,833 | Not Implemented |
SD0542 # 06 Y:2017 | 06 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,162 | $600 | Not Implemented |
SD0542 # 05 Y:2017 | 05 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,740 | $1,500 | Implemented |
SD0542 # 04 Y:2017 | 04 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,078 | $14,300 | Not Implemented |
SD0542 # 02 Y:2017 | 02 | 2017 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,069 | $31,000 | Implemented |
SD0542 # 01 Y:2017 | 01 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,070 | $9,000 | Not Implemented |
SD0507 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $515 | $983 | Implemented |
SD0507 # 05 Y:2011 | 05 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,758 | $7,385 | Not Implemented |
SD0507 # 04 Y:2011 | 04 | 2011 | INSULATE FEEDWATER TANK | $443 | $400 | Not Implemented |
SD0507 # 03 Y:2011 | 03 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,820 | $2,500 | Not Implemented |
SD0507 # 02 Y:2011 | 02 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,615 | $5,000 | Not Implemented |
SD0507 # 01 Y:2011 | 01 | 2011 | USE PHOTOCELL CONTROLS | $152 | $0 | Implemented |
LM0105 # 01 Y:2006 | 01 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $638 | $0 | Not Implemented |
LM0105 # 05 Y:2006 | 05 | 2006 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $3,978 | $1,000 | Implemented |
LM0105 # 04 Y:2006 | 04 | 2006 | DEVELOP STANDARD OPERATING PROCEDURES | $48,035 | $1,500 | Implemented |
LM0105 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,197 | $250 | Implemented |