Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,948
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0069 # 05 Y:2004 | 05 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $34,560 | $0 | Implemented |
UU0069 # 06 Y:2004 | 06 | 2004 | ELIMINATE/REDUCE AN OPERATION | $76,000 | $180,000 | Not Implemented |
TA0077 # 01 Y:2004 | 01 | 2004 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $42,000 | $0 | Not Implemented |
TA0077 # 02 Y:2004 | 02 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,970 | $0 | Not Implemented |
TA0077 # 03 Y:2004 | 03 | 2004 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $9,104 | $8,650 | Not Implemented |
TA0077 # 04 Y:2004 | 04 | 2004 | RECOVER AND REUSE COOLING WATER | $4,087 | $1,685 | Not Implemented |
TA0077 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,474 | $840 | Not Implemented |
NC0301 # 01 Y:2004 | 01 | 2004 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $39,250 | $10,000 | Not Implemented |
NC0301 # 02 Y:2004 | 02 | 2004 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $32,270 | $2,500 | Not Implemented |
NC0301 # 03 Y:2004 | 03 | 2004 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $9,891 | $17,930 | Not Implemented |
NC0301 # 04 Y:2004 | 04 | 2004 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $17,538 | $27,880 | Not Implemented |
NC0301 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,961 | $3,154 | Not Implemented |
NC0301 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $812 | $100 | Not Implemented |
MS0261 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,624 | $25,372 | Not Implemented |
MS0261 # 02 Y:2004 | 02 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $15,290 | $15,000 | Not Implemented |
MS0261 # 03 Y:2004 | 03 | 2004 | USE RADIANT HEATER FOR SPOT HEATING | $6,881 | $3,275 | Not Implemented |
MS0261 # 04 Y:2004 | 04 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,978 | $2,968 | Not Implemented |
MS0261 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,530 | $1,992 | Not Implemented |
MS0261 # 06 Y:2004 | 06 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,883 | $0 | Not Implemented |
MS0261 # 07 Y:2004 | 07 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $1,491 | $19 | Not Implemented |
MS0261 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,148 | $3,031 | Not Implemented |
MS0261 # 09 Y:2004 | 09 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $881 | $66 | Not Implemented |
MA0559 # 01 Y:2004 | 01 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $239,059 | $699,000 | Not Implemented |
MA0559 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $70,580 | $123,500 | Not Implemented |
MA0559 # 03 Y:2004 | 03 | 2004 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $36,905 | $15,475 | Implemented |