Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

521

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0026 # 01 Y:2002 01 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,166 $1,152 Implemented
LM0026 # 02 Y:2002 02 2002 INSTALL SKYLIGHTS $6,152 $4,400 Implemented
LM0026 # 03 Y:2002 03 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $36,384 $900 Implemented
LM0026 # 04 Y:2002 04 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $494 $250 Implemented
LM0026 # 05 Y:2002 05 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,396 $0 Implemented
LM0026 # 06 Y:2002 06 2002 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $66,667 $0 Not Implemented
LM0026 # 07 Y:2002 07 2002 DEVELOP STANDARD OPERATING PROCEDURES $63,050 $12,200 Not Implemented
LM0025 # 01 Y:2002 01 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,567 $3,850 Not Implemented
LM0025 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,580 $350 Implemented
LM0025 # 03 Y:2002 03 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,564 $456 Not Implemented
LM0025 # 04 Y:2002 04 2002 INSTALL SPECTRAL REFLECTORS / DELAMP $2,122 $3,375 Not Implemented
LM0025 # 05 Y:2002 05 2002 SCHEDULE DELIVERIES ACCORDING TO DEMAND $63,600 $15,000 Implemented
LM0025 # 06 Y:2002 06 2002 DEVELOP STANDARD OPERATING PROCEDURES $31,500 $9,240 Implemented
SD0259 # 01 Y:2000 01 2000 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $20,193 $26,000 Not Implemented
SD0259 # 02 Y:2000 02 2000 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $4,440 $40 Implemented
SD0259 # 03 Y:2000 03 2000 REUSE / RECYCLE/ SELL PAPER PRODUCTS $16,900 $0 Not Implemented
SD0259 # 04 Y:2000 04 2000 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $24,552 $14,000 Not Implemented
SD0259 # 05 Y:2000 05 2000 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $82,000 $0 Not Implemented
SF0202 # 01 Y:2000 01 2000 TURN OFF EQUIPMENT WHEN NOT IN USE $698 $0 Implemented
SF0202 # 02 Y:2000 02 2000 INSTALL OCCUPANCY SENSORS $960 $600 Implemented
SF0202 # 03 Y:2000 03 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,800 $11,610 Not Implemented
SF0202 # 04 Y:2000 04 2000 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $941 $5,000 Not Implemented
SF0202 # 05 Y:2000 05 2000 EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME $5,583 $2,180 Implemented
SF0202 # 06 Y:2000 06 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $11,715 $17,142 Not Implemented
SF0195 # 01 Y:2000 01 2000 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $5,651 $3,306 Not Implemented